6-2-6 Low-pass
Filter
Relevant parameters:
P1 - 08
PFLT
Smooth Constant of Position Command (Low-pass
filter)
Communication Addr.: 0108H
Default: 0
Applicable Control Mode: P
Range: 0~1000 (0: Disabled)
Unit: 10 msec
PFLT
Target position
6-2-7 Timing Chart of Position (Pr) Control Mode
In Pr mode, position command source is DI signal from CN1, i.e. selected by POS0~POS2 and CTRG.
Please refer to 6-2-2 to see the relationship between DI signals and parameters. The following figure is
shown the timing chart of Pr mode:
P8
P3
P2
P1
POS0
POS1
CTRG
SON
External I/O signal
OFF
ON
OFF
ON
ON
OFF
ON
>2ms, can be set by P2-09
POS2
ON
OFF
Internal position
command
1ms