This parameter is used to set the excessive error condition of the drive fault code (Refer to
P0-01). As for the proportion value setting of position excessive error warning condition, please
refer to P2-63)
P2 - 36
POV1
Moving Speed Setting of 1st Position
Communication Addr.: 0224H
Default: 1000
Applicable Control Mode: P
Range: 1~5000
Unit: rpm
(When setting value of P2-36 to P2-43 is higher than 3000 rpm, please set setting value of P1-55
to its max. value)
P2 - 37
POV2
Moving Speed Setting of 2nd Position
Communication Addr.: 0225H
Default: 1000
Applicable Control Mode: P
Range: 1~5000
Unit: rpm
P2 - 38
POV3
Moving Speed Setting of 3rd Position
Communication Addr.: 0226H
Default: 1000
Applicable Control Mode: P
Range: 1~5000
Unit: rpm
P2 - 39
POV4
Moving Speed Setting of 4th Position
Communication Addr.: 0227H
Default: 1000
Applicable Control Mode: P
Range: 1~5000
Unit: rpm
P2 - 40
POV5
Moving Speed Setting of 5th Position
Communication Addr.: 0228H
Default: 1000
Applicable Control Mode: P
Range: 1~5000
Unit: rpm
P2 - 41
POV6
Moving Speed Setting of 6th Position
Communication Addr.: 0229H
Default: 1000
Applicable Control Mode: P
Range: 1~5000
Unit: rpm