![Dell PowerEdge T310 Hardware Owner'S Manual Download Page 49](http://html.mh-extra.com/html/dell/poweredge-t310/poweredge-t310_hardware-owners-manual_81346049.webp)
About Your System
49
The following
DIMMs should
match
in
geometry:
x
,
x
,
...
Invalid memory
configuration. The specified
memory modules do not
match in size, number
of ranks, or number of
data lanes.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 108.
The following
DIMMs should
match
in rank
count:
x
,
x
,
...
The following
DIMMs should
match in size:
x
,
x
,
...
The following
DIMMs should
match
in size
and geometry:
x
,
x
,
...
The following
DIMMs should
match
in size
and rank count:
x
,
x
,
...
Thermal sensor
not detected on
x
A memory module without a
thermal sensor is installed in
the specified memory slot
Replace the memory module.
See "Expansion Cards" on
page 114.
Time-of-day
clock stopped
Faulty battery or faulty chip. See "Troubleshooting the
System Battery" on page 152.
Table 1-3.
System Messages
(continued)
Message
Causes
Corrective Actions
book.book Page 49 Wednesday, August 19, 2009 4:40 PM
Summary of Contents for PowerEdge T310
Page 1: ...Dell PowerEdge T310 Systems Hardware Owners Manual ...
Page 56: ...56 About Your System ...
Page 78: ...78 Using the System Setup Program and UEFI Boot Manager ...
Page 146: ...146 Installing System Components ...
Page 176: ...176 Jumpers and Connectors ...
Page 178: ...178 Getting Help ...
Page 188: ...188 Glossary ...
Page 194: ...194 Index ...