34
About Your System
E1810
Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
See "Troubleshooting a
Hard Drive" on page 160.
E1812
Hard drive ##
removed.
Check drive.
The specified hard drive
has been removed from
the system.
Information only.
E1A14
SAS cable A
failure.
Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 177.
E1A1D
Control panel
USB cable not
detected.
Check cable.
USB cable to the
control panel is
missing or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 177.
E2010
Memory not
detected.
Inspect
DIMMs.
No memory was
detected in the system.
Install memory or reseat
the memory modules.
See "Installing Memory
Modules" on page 111 or
"Troubleshooting System
Memory" on page 155.
E2011
Memory
configuratio
n failure.
Check DIMMs.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
See "Troubleshooting
System Memory" on
page 155.
E2012
Memory
configured
but unusable.
Check DIMMs.
Memory configured,
but is unusable.
See "Troubleshooting
System Memory" on
page 155.
Table 1-2.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
book.book Page 34 Wednesday, August 19, 2009 4:40 PM
Summary of Contents for PowerEdge T310
Page 1: ...Dell PowerEdge T310 Systems Hardware Owners Manual ...
Page 56: ...56 About Your System ...
Page 78: ...78 Using the System Setup Program and UEFI Boot Manager ...
Page 146: ...146 Installing System Components ...
Page 176: ...176 Jumpers and Connectors ...
Page 178: ...178 Getting Help ...
Page 188: ...188 Glossary ...
Page 194: ...194 Index ...