34
About Your System
Table 1-8.
System Messages
Message
Causes
Corrective Actions
Alert! Node
Interleaving
disabled! Memory
configuration does
not support Node
Interleaving.
The memory
configuration does not
support node
interleaving.
The system
will run but with reduced
functionality.
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. See
"General Memory Module
Installation Guidelines" on
page 94. If the problem
persists, see
"Troubleshooting System
Memory" on page 158.
Attempting to
update Remote
Configuration.
Please wait...
Remote Configuration
request has been detected
and is being processed.
Wait until the process is
complete.
BIOS Manufacturing
mode detected.
MANUFACTURING MODE
will be cleared
before the next
boot. System
reboot required
for normal
operation.
System is in
manufacturing mode.
Reboot to take the system
out of manufacturing
mode.
BIOS Update
Attempt Failed!
Remote BIOS update
attempt failed.
Retry the BIOS update. If
the problem persists, see
"Getting Help" on
page 181.
Caution! NVRAM_CLR
jumper is
installed on
system board.
NVRAM_CLR jumper is
installed. CMOS has
been cleared.
Remove the NVRAM_CLR
jumper. See Figure 6-1 for
jumper locations.
Summary of Contents for PowerEdge HX574
Page 1: ...Dell PowerEdge R905 Hardware Owner s Manual ...
Page 10: ...10 Contents 7 Getting Help 181 Contacting Dell 181 Glossary 183 Index 195 ...
Page 44: ...44 About Your System ...
Page 62: ...62 Using the System Setup Program ...
Page 144: ...144 Installing System Components ...
Page 182: ...182 Getting Help ...
Page 194: ...194 Glossary ...