42
About Your System
Warning: Following
faulty DIMMs are
disabled:
CPU
n
: DIMM
n
CPU
n
: DIMM
n
Total memory size
is reduced.
Faulty or improperly
seated memory module(s)
used by CPU
n
.
See "Troubleshooting
System Memory" on
page 158.
Warning! No
microcode update
loaded for
processor
n
Microcode update failed. Update the BIOS firmware.
If the problem persists, see
"Getting Help" on
page 181.
Warning: One or
more faulty DIMMs
found on CPUn
Faulty or improperly
seated memory module(s)
used by CPU
n
.
See "Troubleshooting
System Memory" on
page 158.
Warning: The
installed memory
configuration is
not optimal. For
more information
on valid memory
configurations,
please see the
system
documentation on
the technical
support web site.
Invalid memory
configuration. The system
will run but with reduced
functionality.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 94. If the problem
persists, see
"Troubleshooting System
Memory" on page 158.
Write fault
Write fault on
selected drive
Faulty optical drive, hard
drive, or hard-drive
subsystem.
See "Troubleshooting an
Optical Drive" on page 160
or "Troubleshooting a Hard
Drive" on page 161.
NOTE:
For the full name of an abbreviation or acronym used in this table, see
"Glossary" on page 183.
Table 1-8.
System Messages
(continued)
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge HX574
Page 1: ...Dell PowerEdge R905 Hardware Owner s Manual ...
Page 10: ...10 Contents 7 Getting Help 181 Contacting Dell 181 Glossary 183 Index 195 ...
Page 44: ...44 About Your System ...
Page 62: ...62 Using the System Setup Program ...
Page 144: ...144 Installing System Components ...
Page 182: ...182 Getting Help ...
Page 194: ...194 Glossary ...