28
About Your System
E1812
HDD ##
Removed
Specified hard drive has
been removed from the
system.
Information only.
E1914
DRAC5 Conn2
Cbl
DRAC 5 cable is missing
or unseated.
Reconnect the cable. See
"RAC Card" on page 86.
E1A14
SAS Cable A
SAS cable A is unseated,
missing, or bad.
Check the cable
connection to the SAS
backplane. See "SAS
Backplane Board
Connectors" on page 178.
E1A15
SAS Cable B
SAS cable B is unseated,
missing, or bad.
Check the cable
connection to the SAS
backplane. See "SAS
Backplane Board
Connectors" on page 178.
E1A1C
LOM Mezz
Missing
NIC daughter card is
missing.
Install or reseat the NIC
daughter card.
E2010
No Memory
No memory is installed in
the system.
Install memory modules.
See "System Memory" on
page 94.
E2011
Mem Config
Err
Memory detected, but is
not configurable. Error
detected during memory
configuration.
Check the memory
configuration and
reinstall the memory
modules if necessary. See
"System Memory" on
page 94.
See "Troubleshooting
System Memory" on
page 158.
E2012
Unusable
Memory
Memory is configured,
but not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 158.
Table 1-7.
LCD Status Messages
(continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge HX574
Page 1: ...Dell PowerEdge R905 Hardware Owner s Manual ...
Page 10: ...10 Contents 7 Getting Help 181 Contacting Dell 181 Glossary 183 Index 195 ...
Page 44: ...44 About Your System ...
Page 62: ...62 Using the System Setup Program ...
Page 144: ...144 Installing System Components ...
Page 182: ...182 Getting Help ...
Page 194: ...194 Glossary ...