![Datalogic AV500 Product Reference Manual Download Page 48](http://html2.mh-extra.com/html/datalogic/av500/av500_product-reference-manual_3701702048.webp)
MECHANICAL INSTALLATION
28
AV500 2D CAMERA
Mounting Structure Considerations
Your first task is to mount your AV500 camera. You can provide your own mounting
structure or Datalogic can design one for you. We recommend using a Datalogic mount
‐
ing structure for standard applications.
Your mounting structure must provide the following capabilities:
•
It is adjustable enough for you to move your unit to the optimum position for
proper scanning.
•
It allows a technician access to the camera while it is mounted.
•
It must be as vibration free as possible so as not to affect the scanning accuracy.
•
It is constructed of steel or aluminum.
Maintaining Thermal Performance
All electronic devices and circuitry generate excess heat and thus require thermal man
‐
agement to improve reliability and prevent premature failure. The AV500 is no excep
‐
tion, an internal fan is critical to maintaining AV500 performance. Also, proper clearance
must be provided to the unit. There must be at least 300 mm (12 in) clearance behind
the unit for fan air intake and you must use the mounting bracket provided with your
unit to help maintain proper clearance and air flow.
The fan of the AV500 is a field replaceable part. Request spare part number:
8900006713. Instructions are included.
UNPACKING INSTRUCTIONS
Verify that the AV500 Camera and all the parts supplied with the equipment are present
and intact when opening the packaging; the list of parts includes:
•
AV500 Camera
•
Installation Guide
•
Test Chart
•
Mounting Bracket
The AV500 cannot be mounted parallel to the conveyor belt. A 15 degree angle or more is
required to avoid specular reflection.
There must be at least 300 mm (12 in) clearance behind the unit for fan air intake!
Refer to the
Chapter “Preparing for Electrical Installation” on page 41
and Reference Documenta-
tion for details on connecting your readers to other devices in the system.
When installing several AV500s, take care to position them so that no laser beam or LED
illumination enters the reading window of other barcode reading devices in the system. This
condition could occur more frequently for side mounted applications. If these precautions
are not followed, read rate could be negatively affected. To resolve this problem, it is suffi-
cient to slightly change the inclination and/or position of one of the two devices involved.
Summary of Contents for AV500
Page 1: ...AV500 PRODUCT REFERENCE GUIDE 2D CAMERA...
Page 53: ...MOUNTING PRODUCT REFERENCE GUIDE 33...
Page 73: ...CBX510 CONNECTION BOX PRODUCT REFERENCE GUIDE 53 Photoelectric Sensor to CBX510 NPN...
Page 74: ...ELECTRICAL INSTALLATION 54 AV500 2D CAMERA Photoelectric Sensor to CBX510 PNP...
Page 84: ...ELECTRICAL INSTALLATION 64 AV500 2D CAMERA Photoelectric Sensor to CBX100 and CBX800 NPN...
Page 86: ...ELECTRICAL INSTALLATION 66 AV500 2D CAMERA...
Page 91: ...FOCUSING DEVICE WIRING PRODUCT REFERENCE GUIDE 71 Unpowered Outputs...
Page 113: ...OPERATING MODE PRODUCT REFERENCE GUIDE 93...
Page 203: ...PRODUCT REFERENCE GUIDE 183 12 Click Next Step and the following screen appears...
Page 205: ...PRODUCT REFERENCE GUIDE 185...
Page 218: ...E GENIUS 198 AV500 2D CAMERA...
Page 230: ...E GENIUS 210 AV500 2D CAMERA...
Page 231: ...PRODUCT REFERENCE GUIDE 211...
Page 234: ...E GENIUS 214 AV500 2D CAMERA...
Page 249: ...PRODUCT REFERENCE GUIDE 229...
Page 253: ...PRODUCT REFERENCE GUIDE 233...
Page 260: ...E GENIUS 240 AV500 2D CAMERA...
Page 266: ...E GENIUS 246 AV500 2D CAMERA...
Page 299: ...AV500 CALIBRATION PRODUCT REFERENCE GUIDE 279...
Page 321: ...NOTES...
Page 322: ...NOTES...
Page 323: ...NOTES...