Type
26-0*
Analog I/O Mode
26-
00
Te
rm
in
al
X
42/1
M
ode
[1] V
ol
tag
e
All
se
t-ups
TRUE
-
Uint8
26-
01
Te
rm
in
al
X
42/3
M
ode
[1] V
ol
tag
e
All
set-ups
TRUE
-
Ui
nt8
26-
02
Te
rm
in
al
X
42/5
M
ode
[1] V
ol
tag
e
All
set-ups
TRUE
-
Ui
nt8
26-1
*
An
alog In
put
X42/
1
26-
10
Te
rmi
nal
X
42/
1 Lo
w V
oltage
0.0
7 V
All
se
t-ups
TRUE
-2
Int
16
26-
11
Te
rmi
nal
X
42/
1 Hi
gh
Vo
ltage
10
.0
0 V
All
set-ups
TRUE
-2
Int
16
26-
14
Te
rm.
X
42/
1 Low
R
ef.
/Fe
ed
b.
Value
0.0
00 N/
A
All
set-
ups
TR
U
E
-3
Int
32
26-
15
Te
rm.
X
42/
1
Hig
h R
ef.
/Fe
ed
b.
Value
100.
000 N/
A
All
set-ups
TRUE
-3
Int
32
26-
16
Te
rm.
X
42/
1 Fil
ter Tim
e
Co
nstant
0.
00
1 s
All
set-
ups
TR
U
E
-3
U
int16
26-
17
Te
rm.
X
42/
1
Live
Zero
[1
] E
nab
le
d
All
set-ups
TRUE
-
Ui
nt8
26-2
*
An
alog In
put
X42/
3
26-
20
Te
rmi
nal
X
42/
3 Lo
w V
oltage
0.0
7 V
All
set-ups
TRUE
-2
Int
16
26-
21
Te
rmi
nal
X
42/
3 Hi
gh
Vo
ltage
10.0
0 V
All
set-
ups
TR
U
E
-2
Int
16
26-
24
Te
rm.
X
42/
3
Low
R
ef.
/Fe
ed
b.
Value
0.0
00 N/
A
All
set-ups
TRUE
-3
Int
32
26-
25
Te
rm.
X
42/
3 Hig
h
R
ef.
/Fe
ed
b.
Value
100.
000 N/
A
All
set-
ups
TR
U
E
-3
Int
32
26-
26
Te
rm.
X
42/
3 Fil
ter Tim
e
Co
nstant
0.
00
1 s
All
set-ups
TRUE
-3
Ui
nt1
6
26-
27
Te
rm.
X
42/
3
Live
Zero
[1
] E
nab
le
d
All
set-ups
TRUE
-
Ui
nt8
26-3
*
An
alog In
put
X42/
5
26-
30
Te
rmi
nal
X
42/
5 Lo
w V
oltage
0.0
7 V
All
se
t-ups
TRUE
-2
Int
16
26-
31
Te
rmi
nal
X
42/
5 Hi
gh
Vo
ltage
10
.0
0 V
All
set-ups
TRUE
-2
Int
16
26-
34
Te
rm.
X
42/
5 Low
R
ef.
/Fe
ed
b.
Value
0.0
00 N/
A
All
set-
ups
TR
U
E
-3
Int
32
26-
35
Te
rm.
X
42/
5
Hig
h R
ef.
/Fe
ed
b.
Value
100.
000 N/
A
All
set-ups
TRUE
-3
Int
32
26-
36
Te
rm.
X
42/
5 Fil
ter Tim
e
Co
nstant
0.
00
1 s
All
set-
ups
TR
U
E
-3
U
int16
26-
37
Te
rm.
X
42/
5
Live
Zero
[1
] E
nab
le
d
All
set-ups
TRUE
-
Ui
nt8
26-4
*
An
alog Ou
tp
u
t X42/
7
26-
40
Te
rmi
nal
X
42/
7
Output
[0
] No
op
er
at
io
n
All
set-ups
TRUE
-
Ui
nt8
26-
41
Te
rmi
nal
X
42/
7
Min.
Scal
e
0.00
%
All
set-
ups
TR
U
E
-2
Int
16
26-
42
Te
rmi
nal
X
42/
7 Max
. S
cal
e
10
0.0
0 %
All
set-ups
TRUE
-2
Int
16
26-
43
Te
rmi
nal
X
42/
7 Output Bu
s Co
nt
ro
l
0.00
%
All
set-
ups
TR
U
E
-2
N
2
26-
44
Te
rmi
nal
X
42/
7 Output Ti
me
ou
t
Pr
es
et
0.
00
%
1 set-
up
TRUE
-2
Ui
nt1
6
26-5
*
An
alog Ou
tp
u
t X42/
9
26-
50
Te
rmi
nal
X
42/
9
Output
[0
] No
op
er
at
io
n
All
set-ups
TRUE
-
Ui
nt8
26-
51
Te
rmi
nal
X
42/
9
Min.
Scal
e
0.00
%
All
set-
ups
TR
U
E
-2
Int
16
26-
52
Te
rmi
nal
X
42/
9 Max
. S
cal
e
10
0.0
0 %
All
set-ups
TRUE
-2
Int
16
26-
53
Te
rmi
nal
X
42/
9 Output Bu
s Co
nt
ro
l
0.00
%
All
set-
ups
TR
U
E
-2
N
2
26-
54
Te
rmi
nal
X
42/
9 Output Ti
me
ou
t
Pr
es
et
0.
00
%
1 set-
up
TRUE
-2
Ui
nt1
6
26-6
*
An
alog Ou
tp
u
t X42/
11
26-
60
Te
rmi
nal
X
42/
11
Outp
ut
[0
] No
op
er
at
io
n
All
set-ups
TRUE
-
Ui
nt8
26-
61
Te
rmi
nal
X
42/
11
Mi
n.
Scale
0.00
%
All
set-
ups
TR
U
E
-2
Int
16
26-
62
Te
rmi
nal
X
42/
11
Max.
Scal
e
10
0.0
0 %
All
set-ups
TRUE
-2
Int
16
26-
63
Te
rmi
nal
X
42/
11
Outp
ut
Bus Co
ntrol
0.00
%
All
set-
ups
TR
U
E
-2
N
2
26-
64
Te
rmi
nal
X
42/
11 Outp
ut
Time
ou
t
Pr
es
et
0.
00
%
1 set-
up
TRUE
-2
Ui
nt1
6
3.1.22.
26-** Analog I/O Option MCB 109
3. Parameter Lists
VLT
®
AQUA Drive Programming Guide
286
MG.20.O2.02 - VLT
®