Pa
r. No.
#
Pa
ramet
er de
sc
ription
De
fa
ul
t v
alu
e
4-
se
t-
up
Cha
nge
duri
ng
op
era
-
tio
n
Conv
er-
sio
n index
Typ
e
1-0*
Gen
er
al Set
ti
n
g
s
1-
00
Con
fig
uration Mode
null
Al
l se
t-
ups
TR
U
E
-
Uint8
1-
03
Torque Chara
cteristi
cs
[3] Aut
o Energ
y Op
tim.
V
T
Al
l set-ups
TR
UE
-
Ui
nt8
1-2*
Mot
o
r D
ata
1-
20
Moto
r Po
we
r [kW]
SR
Al
l set-ups
FALSE
1
Ui
nt3
2
1-
21
Mo
tor P
ow
er [HP
]
SR
Al
l set-ups
FALSE
-2
Uint32
1-
22
Motor V
oltage
SR
Al
l set-ups
FALSE
0
Ui
nt1
6
1-
23
Mo
tor Freq
ue
nc
y
SR
Al
l set-ups
FALSE
0
U
int16
1-
24
Moto
r Current
SR
Al
l set-ups
FALSE
-2
Ui
nt3
2
1-
25
Mo
tor No
minal
Sp
ee
d
SR
Al
l set-ups
FALSE
67
Uint16
1-
28
Moto
r Ro
tat
ion
Check
[0
] O
ff
Al
l set-ups
FALSE
-
Ui
nt8
1-
29
Auto
matic
Motor Adaptat
ion
(AMA)
[0
] O
ff
Al
l set-ups
FALSE
-
Ui
nt8
1-3*
Ad
v.
M
o
to
r
Dat
a
1-
30
St
ator R
esi
st
ance
(R
s)
SR
Al
l set-ups
FALSE
-4
Uint32
1-
31
Ro
tor Resi
stan
ce
(
R
r)
SR
Al
l set-ups
FALSE
-4
Ui
nt3
2
1-
35
Main R
eactan
ce (X
h)
SR
Al
l set-ups
FALSE
-4
Uint32
1-
36
Iron L
oss R
esist
ance
(Rfe
)
SR
Al
l set-ups
FALSE
-3
Ui
nt3
2
1-
39
Mo
tor P
ole
s
SR
Al
l set-ups
FALSE
0
U
int8
1-5*
Load
In
de
p.
Set
ti
n
g
1-
50
Moto
r
Mag
neti
sati
on at Zero
Sp
eed
100
%
Al
l se
t-
ups
TR
U
E
0
Uint16
1-
51
Mi
n
Sp
eed
Norm
al
Magnetisi
ng [
R
PM]
SR
Al
l set-ups
TR
UE
67
Ui
nt1
6
1-
52
Mi
n Sp
ee
d
No
rma
l Ma
gne
tisi
ng
[
H
z]
SR
Al
l set-up
s
TRU
E
-1
U
int16
1-6*
Load De
pen
. S
et
ti
n
g
1-
60
Lo
w
Sp
ee
d Loa
d Compen
sation
100
%
Al
l se
t-
ups
TR
U
E
0
Int16
1-
61
H
ig
h
Sp
ee
d Loa
d Compensa
tion
100
%
Al
l set-ups
TR
UE
0
Int1
6
1-
62
Sli
p Co
mp
en
satio
n
0 %
Al
l se
t-
ups
TR
U
E
0
Int16
1-
63
Slip Compe
nsation Tim
e Consta
nt
0.1
0 s
Al
l set-ups
TR
UE
-2
Ui
nt1
6
1-
64
R
eso
nance
Damp
eni
ng
100
%
Al
l set-up
s
TRU
E
0
U
int16
1-
65
Re
sona
nce D
ampen
ing Time
Co
nstan
t
5 m
s
Al
l set-ups
TR
UE
-3
Ui
nt8
1-7*
S
tart
Ad
ju
st
men
ts
1-
71
St
art Delay
0.
0 s
Al
l set-ups
TR
UE
-1
Ui
nt1
6
1-
73
Fl
yi
ng S
tart
[0
] Disabled
All
se
t-
ups
FALSE
-
U
int8
1-8*
Stop
Adj
u
st
men
ts
1-
80
Funct
ion a
t Sto
p
[0] C
oast
Al
l se
t-
ups
TR
U
E
-
Uint8
1-
81
Mi
n
Speed for Function at Stop
[R
PM]
SR
Al
l set-ups
TR
UE
67
Ui
nt1
6
1-
82
Mi
n
Sp
ee
d fo
r Functio
n at
St
op
[Hz]
SR
Al
l set-up
s
TRU
E
-1
U
int16
1-9*
M
o
to
r
Te
mper
atu
re
1-
90
Moto
r The
rmal
Prot
ection
[4
] E
TR
tr
ip
1
Al
l se
t-
ups
TR
U
E
-
Uint8
1-
91
Moto
r Ex
te
rna
l Fan
[0] No
Al
l set-ups
TR
UE
-
Ui
nt1
6
1-
93
Thermi
stor So
ur
ce
[0] No
ne
Al
l se
t-
ups
TR
U
E
-
Uint8
3.1.3.
1-** Load/Motor
3. Parameter Lists
VLT
®
AQUA Drive Programming Guide
260
MG.20.O2.02 - VLT
®
is a registered Danfoss trademark
3