![background image](http://html1.mh-extra.com/html/daikin/vrv-x-rxq6-48anr-series/vrv-x-rxq6-48anr-series_service-manual_4705220286.webp)
Check
SiME341909EA
280
Part 6 Service Diagnosis
FXMQ-AR
FXAQ-AR
White (1)
Red (6)
Orange (3)
φ
1
φ
3
(2)
Yellow
(4)
Blue
φ
2
φ
4
M
Orange
White
Yellow Red
(1)
(2)
(6)
—
Blue
(3)
(4)
(5)
Measuring points
Judgment criteria
1-2
No continuity
1-3
300
Ω
1-6
150
Ω
2-4
300
Ω
2-6
150
Ω
White (1)
Red (5)
Orange (3)
φ
1
φ
3
Yellow
(2)
Brown
(6)
Blue
(4)
φ
2
φ
4
M
(1) White
(2) Yellow
(3) Orange
(4) Blue
(6) Brown
(5) Red
Measuring point
Judgment criteria
1-2
No continuity
1-3
300
Ω
1-5
150
Ω
2-4
300
Ω
2-6
150
Ω