Option List
Si37-701
408
Appendix
Building Management System
Notes:
★
1. BACnet
®
is a registered trademark of American Society of Heating, Refrigerating and Air-
Conditioning Engineers (ASHRAE).
★
2. LONWORKS
®
‚ is a registered trade mark of Echelon Corporation.
★
3. Installation box for
adaptor must be procured on site.
No.
Part name
Model No.
Function
1
intelligent Touch
Controller
Basic
Hardware
intelligent Touch
Controller
DCS601C51
• Air-Conditioning management system that can be controlled by a
compact all-in-one unit.
1-1
Option
Hardware
DIII-NET plus adaptor
DCS601A52
• Additional 64 groups (10 outdoor units) is possible.
1-2
Software
P. P. D.
DCS002C51
• P. P. D.: Power Proportional Distribution function
1-3
Web
DCS004A51
• Monitors and controls the air conditioning system using the Internet
and a Web browser application on a PC.
1-4
Electrical box with earth terminal (4 blocks)
KJB411A
• Wall embedded switch box.
2
intelligent
Manager III
Basic
Hardware
Number of
units to be
connected
128 units
DAM602B52
• Air conditioner management system that can be controlled by
personal computers.
256 units
DAM602B51
512 units
DAM602B51x2
768 units
DAM602B51x3
1024 units
DAM602B51x4
2-1
Option
Software
P.P.D.
DAM002A51
• Power Proportional Distribution function
2-2
Web
DAM004A51
• Monitors and controls the air conditioning system using the Internet
and a Web browser application on a PC.
2-3
Eco
DAM003A51
• ECO (Energy saving functions.)
2-4
Optional DIII Ai unit
DAM101A51
• External temperature sensor for intelligent Manager III.
2-5
Di unit
DEC101A51
• 8 pairs based on a pair of On/Off input and abnormality input.
2-6
Dio unit
DEC102A51
• 4 pairs based on a pair of On/Off input and abnormality input.
3
C
o
m
m
u
n
ica
tio
n
lin
e
*1 Interface for use in BACnet
®
DMS502B51
• Interface unit to allow communications between VRV and BMS.
Operation and monitoring of air-conditioning systems through
BACnet
®
communication.
3-1
Optional DIII board
DAM411B51
• Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET
communication ports. Not usable independently.
3-2
Optional Di board
DAM412B51
• Expansion kit, installed on DMS502B51, to provide 16 more
wattmeter pulse input points. Not usable independently.
4
*2 Interface for use in LONWORKS
®
DMS504B51
• Interface unit to allow communications between VRV and BMS.
Operation and monitoring of air-conditioning systems through
LONWORKS
®
communication.
5
C
o
nta
c
t/a
nal
o
g
si
g
nal
Parallel interface
Basic unit
DPF201A51
• Enables ON/OFF command, operation and display of malfunction;
can be used in combination with up to 4 units.
6
Temperature
measurement units
DPF201A52
• Enables temperature measurement output for 4 groups; 0-5VDC.
7
Temperature
setting units
DPF201A53
• Enables temperature setting input for 16 groups; 0-5VDC.
8
Unification adaptor for
computerized control
★
DCS302A52
• Interface between the central monitoring board and central control
units.
[
Summary of Contents for VRV III REYQ8PY1
Page 1: ...REYQ8 48PY1 R 410A Heat Recovery 50Hz Si37 701...
Page 59: ...Specifications Si37 701 48 Specifications...
Page 105: ...Refrigerant Flow for Each Operation Mode Si37 701 94 Refrigerant Circuit...
Page 230: ...Si37 701 Troubleshooting by Remote Controller Troubleshooting 219...
Page 374: ...Si37 701 Piping Diagrams Appendix 363 REYQ14P 16PY1 3D058153A S2NPL S1NPH...
Page 375: ...Piping Diagrams Si37 701 364 Appendix REMQ8PY1 3D057743...
Page 376: ...Si37 701 Piping Diagrams Appendix 365 REMQ10PY1 12PY1 3D057742...
Page 377: ...Piping Diagrams Si37 701 366 Appendix REMQ14PY1 16PY1 3D057741...
Page 382: ...Si37 701 Piping Diagrams Appendix 371 1 3 BS Unit 4D057985A...
Page 384: ...Si37 701 Wiring Diagrams for Reference Appendix 373 REYQ14 16PY1 3D056774C...
Page 385: ...Wiring Diagrams for Reference Si37 701 374 Appendix REMQ8PY1 3D055307E...
Page 386: ...Si37 701 Wiring Diagrams for Reference Appendix 375 REMQ10 12PY1 3D055308E...
Page 387: ...Wiring Diagrams for Reference Si37 701 376 Appendix REMQ14P 16PY1 3D055309E...
Page 392: ...Si37 701 Wiring Diagrams for Reference Appendix 381 FXCQ40M 50M 80M 125MVE 3D039557A...
Page 394: ...Si37 701 Wiring Diagrams for Reference Appendix 383 FXZQ20M 25M 32M 40M 50M8V1B 3D038359...
Page 395: ...Wiring Diagrams for Reference Si37 701 384 Appendix FXKQ25MA 32MA 40MA 63MAVE 3D039564C...
Page 399: ...Wiring Diagrams for Reference Si37 701 388 Appendix FXDYQ180M 200M 250MV1...
Page 402: ...Si37 701 Wiring Diagrams for Reference Appendix 391 FXMQ200MA 250MAVE 3D039621B...
Page 403: ...Wiring Diagrams for Reference Si37 701 392 Appendix FXHQ32MA 63MA 100MAVE 3D039801D...
Page 406: ...Si37 701 Wiring Diagrams for Reference Appendix 395 2 4 BS Unit 3D055928C...
Page 423: ...Piping Installation Point Si37 701 412 Appendix...
Page 427: ...Example of Connection R 410A Type Si37 701 416 Appendix...
Page 433: ...Method of Checking the Inverter s Power Transistors and Diode Modules Si37 701 422 Appendix...
Page 447: ...Si37 701 iv Index...
Page 451: ...Si37 701 viii Drawings Flow Charts...