![Daikin VRV III REYQ8PY1 Service Manual Download Page 166](http://html1.mh-extra.com/html/daikin/vrv-iii-reyq8py1/vrv-iii-reyq8py1_service-manual_3513203166.webp)
Si37-701
Test Operation
Test Operation
155
[Shutoff Valve Operation Procedure]
When operating the shutoff valve, follow the procedure instructed below.
Note:
Do not open the shutoff valve until “1.2.1 Check work prior to turn power supply on” in page
149 are completed. If the shutoff valve is left open without turning on the power, it may cause
refrigerant to buildup in the compressor, leading insulation degradation.
Be sure to use the correct tools.
The shutoff valve is not a back-seat type. If forced it to open, it might break the valve body.
When using a service port, use the charge hose.
After tightening the cap, make sure no refrigerant gas is leaking.
[Tightening torque]
The sizes of the shutoff valves on each model and the tightening torque for each size are listed
in the table below.
<Size of Shutoff Valve>
REYQ8~16PY1
REYQ18~48PY1
8HP type
10HP type
12HP type
14HP type
16HP type
Liquid pipe shutoff valve
φ
9.5
φ
12.7
The 12HP type corresponds to the 12.7-
diameter onsite piping using the accessory
pipe.
Suction gas shutoff valve
φ
25.4
The 8HP type corresponds to the 19.1-diameter onsite piping using the
accessory pipe.
The 10HP type corresponds to the 22.2-diameter onsite piping using the
accessory pipe.
The 12-16 HP type corresponds to the 28.6-diameter onsite piping using
the accessory pipe.
HP/LP gas shutoff valve
φ
19.1
The 8HP type corresponds to the 15.9-diameter onsite piping using the
accessory pipe.
The 14·16 HP type corresponds to the 22.2-diameter onsite piping using
the accessory pipe.
8HP type
10HP type
12HP type
14HP type
16HP type
Liquid pipe shutoff valve
φ
9.5
φ
12.7
The 12HP type corresponds to the 12.7-
diameter onsite piping using the accessory
pipe.
Suction gas shutoff valve
φ
25.4
The 8 · 10HP type corresponds to the 22.2-diameter onsite piping using
the accessory pipe.
The 12-16 HP type corresponds to the 28.6-diameter onsite piping using
the accessory pipe.
HP/LP gas shutoff valve
φ
19.1
The 14 · 16 HP type corresponds to the 22.2-diameter onsite piping
using the accessory pipe.
Equalizer pipe shutoff
valve
φ
19.1
Summary of Contents for VRV III REYQ8PY1
Page 1: ...REYQ8 48PY1 R 410A Heat Recovery 50Hz Si37 701...
Page 59: ...Specifications Si37 701 48 Specifications...
Page 105: ...Refrigerant Flow for Each Operation Mode Si37 701 94 Refrigerant Circuit...
Page 230: ...Si37 701 Troubleshooting by Remote Controller Troubleshooting 219...
Page 374: ...Si37 701 Piping Diagrams Appendix 363 REYQ14P 16PY1 3D058153A S2NPL S1NPH...
Page 375: ...Piping Diagrams Si37 701 364 Appendix REMQ8PY1 3D057743...
Page 376: ...Si37 701 Piping Diagrams Appendix 365 REMQ10PY1 12PY1 3D057742...
Page 377: ...Piping Diagrams Si37 701 366 Appendix REMQ14PY1 16PY1 3D057741...
Page 382: ...Si37 701 Piping Diagrams Appendix 371 1 3 BS Unit 4D057985A...
Page 384: ...Si37 701 Wiring Diagrams for Reference Appendix 373 REYQ14 16PY1 3D056774C...
Page 385: ...Wiring Diagrams for Reference Si37 701 374 Appendix REMQ8PY1 3D055307E...
Page 386: ...Si37 701 Wiring Diagrams for Reference Appendix 375 REMQ10 12PY1 3D055308E...
Page 387: ...Wiring Diagrams for Reference Si37 701 376 Appendix REMQ14P 16PY1 3D055309E...
Page 392: ...Si37 701 Wiring Diagrams for Reference Appendix 381 FXCQ40M 50M 80M 125MVE 3D039557A...
Page 394: ...Si37 701 Wiring Diagrams for Reference Appendix 383 FXZQ20M 25M 32M 40M 50M8V1B 3D038359...
Page 395: ...Wiring Diagrams for Reference Si37 701 384 Appendix FXKQ25MA 32MA 40MA 63MAVE 3D039564C...
Page 399: ...Wiring Diagrams for Reference Si37 701 388 Appendix FXDYQ180M 200M 250MV1...
Page 402: ...Si37 701 Wiring Diagrams for Reference Appendix 391 FXMQ200MA 250MAVE 3D039621B...
Page 403: ...Wiring Diagrams for Reference Si37 701 392 Appendix FXHQ32MA 63MA 100MAVE 3D039801D...
Page 406: ...Si37 701 Wiring Diagrams for Reference Appendix 395 2 4 BS Unit 3D055928C...
Page 423: ...Piping Installation Point Si37 701 412 Appendix...
Page 427: ...Example of Connection R 410A Type Si37 701 416 Appendix...
Page 433: ...Method of Checking the Inverter s Power Transistors and Diode Modules Si37 701 422 Appendix...
Page 447: ...Si37 701 iv Index...
Page 451: ...Si37 701 viii Drawings Flow Charts...