12
Technical data
Installation and operating instructions
57
Daikin/ROTEX A2 F
Oil condensing boiler A2 F
008.1546499_02 – 04/2018 – EN
12.1.2
Information on the type plate
Fig. 12-1
Information on type plate
Item
Designation
Item
Designation
1
Device type
9
Electrical power con-
sumption P
el,max
2
Device type
10
Protection type
3
Product ID
11
Empty weight
4
Rated thermal load Q
n
(combustion perform-
ance)
12
Total filled weight
5
Nominal heat output P
n
(80/60 °C) [EN 303]
13
Max. permissible oper-
ating pressure PMS
(heating)
6
Nominal heat output
with condensation P
nc
(50/30 °C)
14
Max. permissible oper-
ating temperature T
max
7
NO
X
class (EN 267)
15
Production number
(specify with com-
plaints and queries)
8
Voltage supply U
16
Date of production
Tab. 12-5
Legend for
Fig. 12-1
12.1.3
Data sheets according to Ecolabel and
Ecodesign regulation (EU) 811/2013
Boiler type
A2 F 18H
A2 F 24H
A2 F 32H
Parameters
Unit
Class of seasonal space heating energy effi-
ciency
A
A
A
Rated heat output P
rated
kW
18
24
31
Seasonal space heating energy efficiency η
S
%
91
92
93
Annual energy consumption Q
HE
GJ
41
54
68
Noise power level L
WA
dB(A)
63
65
66
Tab. 12-6
Product data sheet A2 F
Type integrated temperature controller
RoCon B1 / BM2
Parameters
Unit
Class of the temperature con-
troller
II
Contribution to the seasonal
space heating energy effi-
ciency
%
2.0
Tab. 12-7
Product data sheet integrated control RoCon B1 / BM2
Type of connected room station
RoCon U1
Parameters
Unit
Class of the temperature con-
troller
VI
Contribution to the seasonal
space heating energy effi-
ciency
%
4.0
Tab. 12-8
Product data sheet control unit A2 F + connected room
station RoCon U1
Special precautions for installation and maintenance can be found in
the installation and operating instructions. Energy efficiency labels
and product data sheets for additional combinations, packages and
other products can be found at
www.rotex-heating.com
or
https://en-
ergylabel.daikin.eu
.
Noise level in heating mode, measured according to EN 15036 un-
der the conditions of EN ISO 3746, accuracy class 3. This data
serves to compare the energy efficiency according to the Energy La-
belling Directive 2010/30 EC. For the correct selection of products
for your application, contact your dealer.