12
Technical data
Installation and operating instructions
61
Daikin/ROTEX A2 F
Oil condensing boiler A2 F
008.1546499_02 – 04/2018 – EN
Item
Designation
Item
Designation
OPH
Oil preheater
OMCB-
Power supply for oil pump control unit
OMV
Oil solenoid valve
OPS
Oil pump pressure sensor
FID
Ignition transformer flame monitoring
OECB
Data cable (firing unit – oil pump control unit)
TRA-X2
Ignition of ignition transformer
OPM-
Power supply for oil pump
P
Z
Circulation pump (optional)
Q
1
Device main switch
3UVB1
3-way mixer valve
F1
Fuse
3UV DHW
3-way distribution valve
STBK
Safety temperature limiter
3UV1
3-way valve
BF
Burner blower mains connection
AUX
Output for special functions
BF-PWM
Burner blower speed regulation
RoCon U1
(EHS157034)
Room station (optional)
CM471
Firing unit
RoCon M1
(EHS157068)
Mixer circuit control (optional)
J1
3-pin circuit board connector with mains pump cable
FLS
Flow sensor (boiler circuit)
J2
4-pin circuit board connector: Connection of 3-way
mixer valve 3UVB1
EXT
Input for external operating mode switching
J3
6-pin circuit board connector (AUX connection for spe-
cial functions)
EBA
Floating switch contact for external heat request
J4
3-pin circuit board connector (not occupied)
t
V1
Inflow temperature sensor (boiler circuit)
J5
3-pin circuit board connector with pressure sensor
cable
t
V2
Internal mixer sensor = inflow temperature sensor
(heating circuit)
J6
4-pin circuit board connector with clamped mains cable
and earthing slots
t
R
Return flow temperature sensor
J7
2-pin circuit board connector with PWM signal cable for
heating circulation pump
t
AU
External temperature sensor
J8
12-pin circuit board connector for connecting sensors
and control lines
t
DHW
Storage tank temperature sensor
J9
5-pin circuit board connector (not assigned)
RT/RT-E
Room thermostat (optional)
J10
3-pin circuit board connector with mains cable for
CM471 firing unit
RoCON BE2
Circuit board
J11
5-pin circuit board connector with communications
cable for CM471 firing unit
RJ45-CAN
(BU1)
BUS – control panel connection
J12
4-pin circuit board connector: Connection of 3-way
mixer valve 3UV DHW
S3
DIP switch (device type)
J13
4-pin circuit board connector for connection of addi-
tional controller components (CAN bus)
S5
DIP switch (1=on; 2=off; 3,4=off if Smart Start kit is in-
stalled)
J14
3-pin circuit board connector for clamping a circulation
pump
RoCon B1
Control panel
J15
4-pin circuit board connector with switch cable
DS
Pressure sensor
J16
4-pin circuit board connector for connection of a room
thermostat (digital request contact)
P
K
Heating circulation pump
Mains voltage 230 V, 50 Hz
PWM (P
K
)
Speed controller for P
K
Tab. 12-15 Wiring diagram legend A2 F