Technical data
Installation and operating instructions
56
Daikin/ROTEX A2 F
Oil condensing boiler A2 F
008.1546499_02 – 04/2018 – EN
Boiler type
A2 F 18H
A2 F 24H
A2 F 32H
Burner type
Firing unit
Honeywell CM471
Ignition transformer with flame monitor
Federal Mogul ZTÜ No. 0 096 600 024: 2x 7.5 kV, 15 – 20 kH
Oil motor pump unit
Danfoss type BFPM-61 motor pump unit
Oil preheating
Danfoss type FPHE5, PTC50, T60/32
Fan
ebmpapst HRG134
Tab. 12-3
Type designation of the burner components
12.1.1
Integrated heating circulation pump, 3-way valves
Parameters
Unit
Heating circulation pump
Type
Grundfos UPM3K 25-75 CHBL RT
Voltage
V
~230
Frequency (voltage supply)
Hz
50
Maximum power consumption
W
60
Protection type
IP X4D
Permitted overpressure
bar
3
Maximum pumping height
m
7.5
Energy efficiency
EEI<0.2 (EN 16297‑3)
3-way valves: 3UV DHW / 3UVB1
Type
AFRISO USV
Voltage
V
~230
Frequency (voltage supply)
Hz
50
Maximum power consumption
W
7
Protection type
IP 54
Turnaround time
s
75
Tab. 12-4