4
Set-up and installation
Installation and operating instructions
11
Daikin/ROTEX A2 F
Oil condensing boiler A2 F
008.1546499_02 – 04/2018 – EN
4
Set-up and installation
WARNING
Devices which have been set-up and installed incorrectly
may not operate properly and can be a health and safety
risk endangering human life.
▪ Only authorised and trained heating technicians may set
up and install the A2 F.
4.1
Dimensions and connection
dimensions
A
736
A
606
271
2
6
2
1
3
6
0
1
3
4
263
140
1
4
0
80
0
0
110
293
368
442
516
540
5
0
1
2
4
R
H
Fig. 4-1
Installation dimensions
Item
Designation
R
H
Minimum room height (see
Chap. 4.4.1
)
Tab. 4-1
Legend for
Fig. 4-1
INFORMATION
To avoid increased cooling losses, we recommend the in-
stallation of
SKB gravity brakes (accessory)
or the sy-
phoning of the connection line.
4.2
Different set-ups
≥
4
0
c
m
≥
4
0
cm
≥ 40 cm
≥
2
0
0
cm
CA
FG
RV
(e)
(e)
(d)
(d)
(f)
(a)
1
(a)
4
(a)
3
(b)
5
(c)
6
(a)
2
C
93
C
53
C
53
C
83
C
33
C
33
B
23
B
23P
B
33
B
53
B
53P
Fig. 4-2
Different set-ups
Item
Designation
1-6
Installation versions (for a description, see
Chap. 4.2.1
to
Chap. 4.2.3
)
CA
Supply air (combustion air)
FG
Flue gas
RV
Rear ventilation
a
Installation version for ambient air-independent opera-
tion (flue gas/supply air concentric)
b
Installation version for conditional ambient air-independ-
ent operation (flue gas/supply air separate)
c
Installation version for ambient air-dependent mode
d
Longitudinally ventilated shaft with a fire-resistance
period of 90 minutes (30 minutes in low height residen-
tial buildings). Observe country-specific regulations for
fire-resistance periods!
e
Ventilation opening (1x150 cm
2
or 2x75 cm²)
f
Rear ventilation opening (150 cm
2
)
Tab. 4-2
Legend for
Fig. 4-2
The A2 F is designed for
ambient air-independent
operation. It is
fitted as standard with a concentric flue gas /air supply pipe DN
80/125.
INFORMATION
In some cases, the resonance in the flue gas system can
amplify the noise at the mouth of the flue gas duct. The
noise level can be effectively reduced by using a silencer
(accessory:
DN 80: E8
MSD
or
DN 110:
E11 MSD
).