Document Number: 002-10635 Rev. *I
Page
267 of 325
S6J3310/20/30/40 Series
Page
Section
Change Results
81
7. Port
Configuration
7.1 Resource
Input
Configuration
Module
Revised as below:
Error)
RIC_RESIN235(0x01D6)
OCU1_CK0, OCU1_CK1, OCU1_DOWNB0, OCU1_DOWNB1, OCU1_FCMD0, OCU1_FCMD1,
OCU1_MTSF0, OCU1_MTSF1, OCU1_T0[31:0], OCU1_T1[31:0]
RIC_RESIN236(0x01D8)
OCU1_ZTSF0, OCU1_ZTSF1, OCU1_MOD0
Correct)
RIC_RESIN235(0x01D6)
OCU1_CK0, OCU1_CK1, OCU1_DOWNB0, OCU1_DOWNB1, OCU1_FCMD0, OCU1_FCMD1,
OCU1_MTSF0, OCU1_MTSF1, OCU1_T0[31:0], OCU1_T1[31:0], OCU1_ZTSF0, OCU1_ZTSF1
RIC_RESIN236(0x01D8)
OCU1_MOD0
155
8.Precautions
and Handling
Devices
8.1.1Precautio
ns for Product
Design
Revised as below:
Error)
(1) Preventing Over-Voltage and Over-Current Conditions
Exposure to voltage or current levels in excess of maximum ratings at any pin is likely to cause
deterioration within the device, and in extreme cases leads to permanent damage of the device. Try to
prevent such overvoltage or over-current conditions at the design stage.
Correct)
(1) Preventing Over-Voltage and Over-Current Conditions
Exposure to voltage or current levels in excess of maximum ratings at any pin is likely to cause
deterioration within the device and in extreme cases leads to permanent damage of the device. Try to
prevent such overvoltage or over-current conditions at the design stage.
156
8.Precautions
and Handling
Devices
8.1.2Precautio
ns for Package
Mounting
Revised as below:
Error)
Surface Mount Type
Correct)
Surface Mount Type
159
9.Electric
Characteristics
9.1.1 Absolute
Maximum
Rating
Deleted Remarks comment as below:
Error)
Supply voltage
Operation assurance range, DV
CC
, Remarks “DV
CC
≤V
CC
5”
Correct)
Power supply voltage, DV
CC
, Remarks “”
159
8.2Handling
Devices
Added Note of a function as below:
Method to Switch off VCC12 during Power-off Sequence
During power-off sequence, it is necessary to switch off VCC12 by driving PSC1 pin low by entering PSS
mode (power domain 2 off). If VCC12 needs to be switched off by other means, RSTX needs to be
asserted before switching off VCC12 to inactivate the operation of VCC12 supplied domain below the
operation assurance range.