Document Number: 002-10635 Rev. *I
Page
298 of 325
S6J3310/20/30/40 Series
Page
Section
Change Results
Correct)
Parameter
Symbol
Pin
Name
Conditions
Value
Unit
Remarks
Min
Typ
Max
Supply
voltage
range
V
RDP5
-
-
1.05
-
1.21
V
Detection
voltage
(before
trimming)
V
RDLBT
-
*1 *2
0.775
0.875
0.975
V
When power-
supply voltage
falls
Detection
voltage
(after
trimming)
V
RDLAT
-
*1 *2
0.844
0.875
0.906
V
When power-
supply voltage
falls
Typ±3.5%
Hysteresis
width
V
RHYS
-
-
-
75
-
mV
When power-
supply voltage
rises
Low-
voltage
detection
time
TRd
-
-
-
-
30
μs
*3
*2: This LVD cannot be used to reliably generate a reset before voltage dips below minimum guaranteed
MCU operation voltage, as these detection levels are below the minimum guaranteed MCU operation
voltage.
*3: After the brown-out event where the voltage level dips below the detection threshold for less than this
time, the detection may occur or be canceled.
248
9. Electric
Characteristics
9.1.4.21 LCD
bus I/F
Error)
-
Correct)
All change
249
250
251
252
9. Electric
Characteristics
9.1.4.22
Pow
er and Reset
Sequence
Error)
-
Correct)
Newly added