Document Number: 002-10635 Rev. *I
Page
313 of 325
S6J3310/20/30/40 Series
Page
Section
Change Results
266
9. Electric
Characteristics
9.1.7.1 Electrical
Characteristics
Error)
Parameter
Rating
Unit
Remarks
Min
Typ
Max
*3
Sector erase time
-
120
180
ms
Large sector*1
Internal preprogramming time included
-
120
180
ms
8kB sector*1
Internal preprogramming time included
-
120
180
ms
4kB sector
*1
Internal preprogramming time included
16bit write time(Program)
-
30
60
µs
System-level overhead time excluded
*1
32bit write time(Program)
-
30
60
µs
System-level overhead time excluded
*1
64bit write time(Program)
-
30
60
µs
System-level overhead time excluded
*1
256bit write time(Program)
-
40
70
µs
System-level overhead time excluded
*1
Page mode write
time(Program)
-
320
600
µs
System-level overhead time excluded
*1
32bit write time(Work)
-
30
60
µs
System-level overhead time excluded
*1
Erase count /
Data retention time(Program)
*3
1,000/20
years
-
-
-
Temperature at write/erase time
Average temperature T
A
=+85 degrees Celsius
Erase count /
Data retention time(Work)
*3
1,000/20
years
10,000/10
years
100,000/5
years
-
-
-
Temperature at write/erase time
Average temperature T
A
=+85 degrees Celsius
*1: Guaranteed value for up to 1,000 erases
*2: Guaranteed value for up to 100,000 erases
*3: Target Value
Correct)
Parameter
Rating
Unit
Remarks
Min
Typ
Max
Sector erase time
-
120
180
ms
Large sector
*1
Internal preprogramming time included
-
120
180
ms
8 kB sector
*1
Internal preprogramming time included
-
120
180
ms
4 kB sector
*2
Internal preprogramming time included
16-bit write time (Program)
-
30
60
µs
System-level overhead time excluded
*1
32-bit write time (Program)
-
30
60
µs
System-level overhead time excluded
*1
64-bit write time (Program)
-
30
60
µs
System-level overhead time excluded
*1
256-bit write time (Program)
-
40
70
µs
System-level overhead time excluded
*1
Page mode write time
(Program)
-
320
600
µs
System-level overhead time excluded
*1
32-bit write time (Work)
-
30
60
µs
System-level overhead time excluded
*2
Erase count /
Data retention time (Program)
1,000/20
years
-
-
-
Temperature at write/erase time
Average temperature T
A
= +85 degrees Celsius
Erase count /
Data retention time (Work)
1,000/20
years
10,000/10
years
100,000/5
years
-
-
-
Temperature at write/erase time
Average temperature T
A
= +85 degrees Celsius
*1: Guaranteed value for up to 1,000 erases