Use and maintenance manual
ZED 23.2 JH
Code n°UM0260_GB
52
ATTENTION:
it is prohibited to use the electric pump with the power take-off
inserted.
To use the machine with electric pump, connect the power supply cable with minimum
section of 2.5x3 mm² and length not exceeding 20 m. Attention, the cable must be
protected to a socket protected by differential switch and plant built in compliance with
the Safety Standards in force . The plant is active. Stabilise the machine as described
in
chap. 4.3.2
.
!
NOTE:
the electric pump is constantly in use during stabilisation, when using
the platform it is only active during movement.
10.7 400V 4.5 kW three-phase auxiliary electric pumps
The machine can be equipped with an auxiliary electric pump powered by electric
current for use in work environments where the use of the endothermic engine is not
allowed.
ATTENTION:
it is prohibited to use the electric pump with the power take-off
inserted
To use the machine with the electric pump, connect the power supply cable with
minimum section of 2.5x3 mm² and length that does not exceed 20 m.
Attention, the cable must be connected to a socket protected by a differential switch
with plant built according to Safety Standards in force. The plant is active.
Stabilise the machine as described in
chap. 4.3.2
.
ATTENTION:
check the correct direction of rotation of the motor (clockwise); in the
case of anti-clockwise rotation, invert it using the polarity selector
switch.
!
NOTE:
the electric pump is constantly in use during stabilisation, when using
the platform it is only active during movement.
Summary of Contents for ZED 23.2 JH
Page 2: ......
Page 13: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 11 2 5 Work area...
Page 47: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 45...
Page 50: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 48 7 HYDRAULIC PLANT LAYOUT...
Page 51: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 49 8 ELECTRIC WIRING DIAGRAM...