Use and maintenance manual
ZED 23.2 JH
Code n°UM0260_GB
51
10
ACCESSORIES
10.1 230V electric socket in work platform
The machine can be equipped with a 230V electric socket in the work platform. To
power the electric socket, connect a power supply cable with minimum section of
2.5x3 mm² and length not exceeding 20 m to the socket situated in the turret.
ATTENTION:
it is prohibited to connect tools with voltage different to 230V and
power exceeding 1.5 kW.
ATTENTION:
before connecting the tool it is mandatory to control the correct
functioning of the differential; the control is made using the test key T.
The differential must trip. Restore the device by lifting the master switch
lever. If this does not occur, do not use the electric socket and contact a
CTE After-sales Centre for repairs.
10.2 Work light
(Only for machines equipped with 230V electric socket on the work platform)
It functions by inserting the 230V plug in the basket and activating the ignition switch.
!
NOTE:
the bulb is low voltage and the plant is equipped with transformer.
10.3 Air/water supply piping
It is an automatic hose reel faired in plastic, with moveable fixing bracket, suitable for
use with air and water (temp. –10°C + 60°C) that can be used with pipes with internal
diameter of 8 mm, external diameter 12 mm and maximum length 15 m. 3/8 air inlet
fittings. Maximum use pressure 20 Bar.
10.4 Man present pedals in W.P.
The machine can be equipped with pedals on the work platform.
If this accessory is not pressed, it deactivates all manoeuvres of the control board.
The pedal must be pressed for the control board to be used and then using the
proportional levers it is possible to perform the desired manoeuvres.
10.5 Fifth wheel rotation block system
The machine can be equipped with an electric device that does not allow to perform
continuous rotation of the EWP, but only up to 350°, thus only permitting to go back to
the starting point.
10.6 230V 2.5 kW single-phase auxiliary electric pumps
The machine can be equipped with an auxiliary electric pump powered by electric
current for use in work environments where the use of the endothermic engine is not
allowed.
Summary of Contents for ZED 23.2 JH
Page 2: ......
Page 13: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 11 2 5 Work area...
Page 47: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 45...
Page 50: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 48 7 HYDRAULIC PLANT LAYOUT...
Page 51: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 49 8 ELECTRIC WIRING DIAGRAM...