Use and maintenance manual
ZED 23.2 JH
Code n°UM0260_GB
18
3
SAFETY
3.1 Declared use conditions
The elevated work platform can be used to carry out jobs at a height, which can be
performed remaining inside the work platform, such as:
•
painting, routine and extraordinary maintenance of buildings
•
maintenance of plants and industrial establishments
•
maintenance on electric lines and installation of electric plants
•
pruning.
The limits for use are described in this manual. Any method and condition of use
outside of the use limits described in the manual, not declared by the manufacturer is
prohibited.
3.2 Environmental limits
The machine can be used in the following environmental conditions:
•
environmental temperature between -10° C and + 40° C
•
humidity 80% at 40° C
•
wind speed below 12.5 m/s(45 km/h)-6° on the Beaufort wind scale (
chap. 9
).
The machine cannot be used in the following environmental conditions:
•
unfavourable atmospheric conditions and little visibility (rain, snow, fog etc.).
•
presence of explosive atmosphere
•
indoor environments with insufficient ventilation
•
little or insufficient lighting (the lighting must be sufficient to cover the entire work
area and allow the stickers on the machine to be read along with the identification
of all controls and emergency devices).
3.3 Safety Standards - obligations and prohibitions
DANGER:
the failure to comply with Safety Standards can cause serious injury and
even death.
OBLIGATION:
it is mandatory to comply with the national Standards in force, the Safety
Standards made by the employer and those relative to the work place.
ATTENTION:
read and understand the Safety Standards before going on the next
chapter.
3.3.1 ELECTROCUTION HAZARD
•
This machine is
not
electrically insulated and
does not
supply protection from the
contact or proximity with electric lines.
•
It is mandatory to comply with the minimum safety distance from the equipment
and live overhead lines as indicated in the
Legislative Decree dated 09 April
2008 n° 81 ATTACHMENT IX
. Failure to comply with the minimum distance can
cause death or serious injury.
•
Table 1 Attachment IX
– safety distances from live parts of electric lines and
plants that are not protected or sufficiently protected
to be complied with when
Summary of Contents for ZED 23.2 JH
Page 2: ......
Page 13: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 11 2 5 Work area...
Page 47: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 45...
Page 50: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 48 7 HYDRAULIC PLANT LAYOUT...
Page 51: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 49 8 ELECTRIC WIRING DIAGRAM...