Use and maintenance manual
ZED 23.2 JH
Code n°UM0260_GB
43
•
Feed the card: the green led will light (DL5) and the displays
(U1-U3) will light up completely for a while.
•
For the first 10 seconds from the ignition, two “_” (U1-U3) will
appear on the displays.
•
Wait 10 seconds until the displays turn off.
•
For the calibration procedure press “SW3” key for at least two
seconds. On the display two numbers “1” will appear.
•
Press the “SW2” key for two seconds to enter the calibration
procedure ; on the two displays will appear intermittently two
“0”. This message means : “ waiting for the recalibration of the
zero”.
•
Switch the system into rest position (empty basket) and press “ SW1” key to obtain
the value of zero.
•
If the load value is between ±10% with respect to zero and
performed with the initial calibration, “1” and “0” will appear on
the displays intermittently confirming the calibration of the zero.
•
If the load value is over ±10% with respect to zero performed
with the initial calibration, “8” will appear on the displays
intermittently
refusing the calibration of the zero
.
•
To exit the calibration procedure press “SW3”, switch the card off and check the
proper use of the device.
ATTENTION:
any malfunctioning of the device or of the calibration procedure,
please contact the Service Centre.
Summary of Contents for ZED 23.2 JH
Page 2: ......
Page 13: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 11 2 5 Work area...
Page 47: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 45...
Page 50: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 48 7 HYDRAULIC PLANT LAYOUT...
Page 51: ...Use and maintenance manual ZED 23 2 JH Code n UM0260_GB 49 8 ELECTRIC WIRING DIAGRAM...