2. Positioning
37
EN
Gas appliances
OGS / OGB
6.10:
155/ 175kg
OGS / OGB
6.20:
215/ 235 kg
OGS / OGB
10.10: 173/ 200 kg
OGS / OGB
10.20: 250/280 kg
OGS / OGB
12.20: 320/*342* kg
OGS / OGB
20.10: 315*/344* kg
OGS / OGB
20.20:404*/458* kg
* = including loading trolley
Electrical appliances
OES / OEB
6.10:
136/155 kg
OES / OEB
6.20:
196/215 kg
OES / OEB
10.10: 165/175 kg
OES / OEB
10.20: 225/245 kg
OES / OEB
12.20: 288*/314* kg
OES / OEB
20.10: 295*/315* kg
OES / OEB
20.20:395*/414* kg
* = including loading trolley
2.1
Prerequisites for Installation
Site
•
Does the combi steamer fit through
passageways and doors
? Indication
for minimum measures of a unit on a
pallet without packing.
•
Unit dimensions (Width x Depth x
Height) with packing (in mm) see
below.
•
Installation site surface
–
The installation surface must be
even and level.
–
The installation site must be able to
hold the weight of the unit (see
below) and the maximum load (see
Operator's Manual).
•
Climate conditions at the installation
site:
–
Must be in accordance with
Work
Place-Decree
!
–
The area temperature must only be
+4°C to +35°C.
–
Do not operate in a poisonous or
explosive atmosphere.
–
Do not operate outdoors without
protection from rain.
•
Do not place the combi steamer near
cooking units such as fryers or units
baking with grease etc.. There is a
high risk of burns to the user when
water sprays in hot grease.
A safety distance must be
maintained from grease holders or
fryers (the working radius of the
hand shower).
•
For sea water conditions, use special
units with option ‚marine version’.
•
Do not install the unit next to flammable
materials. The local
fire safety
regulations
must be adhered to!
2.2
Transport to Installation
site
•
Transport on pallet only!
•
Unit should be moved in upright
position!
•
An inventory/packing list is under the
top of the packing carton.
.
•
Remove all cartons, packing material,
documents, labels, containers and
loading trolley etc. from the oven.
2.3
Remove unit from the pallet
•
Using a high lift truck, lift combi
steamer from the pallet.
Do not tip
!
•
If necessary, use a low lift platform
truck or forklift for bringing the unit into
the right position.
•
Before picking the unit up with a forklift
or low lift truck,
it is necessary to pay
attention to the correct position of
the lifting forks
(stay right of drain (C)
and unit overflow (M)!)
X.10
C = 283 mm / M = 337 mm
X.20
C = 323 mm / M = 375 mm
Electrical appliances & Gas appliances
CONVOTHERM
6.10: 1,130x950x1,040
CONVOTHERM
6.20: 1,410x1,175x1,105
CONVOTHERM
10.10: 1,130x950x1,310
CONVOTHERM
10.20: 1,410x1,175x1,330
CONVOTHERM
12.20: 1,435x1,200x1,650
CONVOTHERM
20.10: 1,150x1,000x2,185
CONVOTHERM
20.20: 1,435x1,200x2,185
Picture 1
Picture 2
Picture 3/4
Picture 3/4
Picture 3/4
Picture 7
Summary of Contents for OEB 10.10
Page 7: ...Notizen 3 DE...
Page 37: ...Notes 33 EN...
Page 67: ...Notes 63 FR...
Page 113: ...Bilder pictures Images Afbeeldingen Figuras 19 6 20 7 21 11 1 22 11 2 23 11 2...
Page 114: ...Bilder pictures Images Afbeeldingen Figuras 24 11 3 25 11 3...
Page 115: ...Bilder pictures Images Afbeeldingen Figuras 26 11 4 27 11 4 28 11 4 29 11 6 30 12 31 12...