7.2.2 Goods scanner GSC3
The input
GSC3
is used to count the goods in the nonstop labelling mode. The input also can be
used to count goods or events. Therefore the counter must be programmed to EXTERNAL. The
input GSC3 will be connected in the traction unit. Figure 23 shows how to connect the GSC3
input.
7.2.3 Control input NSTPI (NonSToP In)
The
NSTPI
input is used for the connection of two Collamat in the nonstop labelling mode. The
wiring of the nonstop mode is described in the chapter nonstop labelling. This input is connected
inside of the traction unit. Figure 23 shows how to connect the NSTPI-input.
7.2.4 Control input STOP
The
STOP
input is used to stop or start the Collamat. It has the same function like the RUN/STOP
key on the control panel. If the signal is activated while the Collamat is stopped, the Collamat will
be started (RUN) and vice versa.
The relais contacts are activated according to the momentary mode. The counting of the goods
will be continued anyway. Error messages will not be cleared. The signal must be connected to
the
CONTROL SIGNALS
connector.
Figure 23 shows how to connect the STOP input.
Figure 23: Connection of photocoupler inputs
All comparator inputs are taken to the
DISPENSER
connector. From there the signals go to the
traction unit. The peripheral units are all connected to the traction unit.
+
GND
OUT
NPN-Sensor
+12V
Anode
Cathode
+
-
GND
+12V
+
GND
OUT
PNP-Sensor
+12V
Anode
Cathode
+
-
GND
+12V
Sensor
Sensor
Monitor
Monitor
5999.545-01G 28.02.2006 WM
Page 30 / 65
Summary of Contents for Etiprint Inline
Page 65: ...Etiprint Inline Manufacturer s declaration Register A Manufacturer s declaration...
Page 66: ...Etiprint Inline Manufacturer s declaration 66...
Page 68: ...Etiprint Inline Manufacturer s declaration 68...
Page 69: ...Etiprint Inline Replacement parts Wear parts Register B Replacement parts Wear parts...
Page 70: ...Etiprint Inline Replacement parts Wear parts 70...
Page 74: ...Etiprint Inline Replacement parts Wear parts 74 Draw mechanism spare parts cont...
Page 78: ...Etiprint Inline Electric circuit drawing with printer type SATO...
Page 79: ......
Page 80: ......
Page 82: ...Etiprint Inline Electric circuit drawing with printer type ZEBRA...
Page 84: ......
Page 86: ...Etiprint Inline Collamat 8600 9100 Monitor Operating instructions...
Page 87: ...Collamat 8600 9100 Operating instructions Monitor 5999 530 01F...
Page 144: ...Etiprint Inline Collamat 8600 9100 Monitor Technical Manual...
Page 145: ...Collamat 8600 Technical handbook 5999 545 01G...
Page 188: ......