Error messages
If during operation an error occurs, this will be indicated on the LCD by an
error mes-
sage
. Each error message has to be acknowledged by the
ENTER
key. If several errors
occur at the same time, they have to be acknowledged one after each other. All events
causing an error message stop the labeller or only a warning message appears. An er-
ror causing a
labeller stop
activates the
ERROR
and
NOK
relay signals. If only a
war-
ning
is indicated, only the
NOK
relay signal is activated. The acknowledgement with the
ENTER
key
deactivates
these signals.
The following table shows all possible error messages with their error number.
Error # Error message
Error cause
1
Not ready
External signal READY not ready
2
TUNIT / Paper end
Traction unit not closed, end of paper reached
3
Position too short
Position value shorter than calculated (speed)
4
Max. speed
Measured speed higher than permitted max. value
5
Label stock
No label stock
6
Rewinder full
Rewinder full
7
No LSC-Adjust
No adjustment of label scanner possible
8
Nonstop mode
Error in one of the labellers in nonstop mode
9
Label too long
Label dispensed longer than entered label length
10
LSC Counter
A further gap was scanned during predispensing
11
Drive not ready
Motor driver card signals an error or is not ready
12
Undervoltage
Undervoltage of mains scanned
13
Profiling speed
Speed higher than max. speed
14
Time observing
Internal processor monitoring
15
Division by zero
Internal software error
16
Predispensing too short Predispensing is too short for the actually measu-
red speed
5999.530-01B 13.08.98 WM
Page 40 /