Value table
Parameter
Value range
Default
Resolution
R/S
P/O
Speed C8600
fixed+measured C9100
0.5-50.0 m/min
0.5-80.0 m/min
3.0
0.1 m/min
R/S
P
Speed with C8600
encoder C9100
0.0-50.0 m/min
0.0-80.0 m/min
-
-
0.1 m/min
R/S
P
Step length of encoder
1.00 - 9.99 mm
1.00
0.01 mm
S
P
Distance measuring light barrier 10.0 - 99.9 mm
14.0
0.1 mm
S
P
Max.speed C8600
C9100
3 - 50 m/min
3 -100 m/min
50
80
1 m/min
S
P
Predispensing C8600
C9100
1 - 250 mm
0.0
10.0
0.1 mm
R/S
P/O
Position
0 - 1000 mm
0
0.1 mm
R/S
P/O
Label scanner sensitivity
0 - 99
40
1
S
P
Label length
5 - 2500 mm
100
1 mm
S
P
Label suppression
0 - 2500 mm
0
1 mm
S
P
Goods suppression
0 - 1000mm
0
1 mm
S
P
Adapter magnet time
(only C9100)
on/off
0.0 - 2.0s
off
0.0
-
0.1 s
S
P
Labelling mode normal
multiple
delayed
on/off
on/off (only C9100)
on/off
on
off
off
-
-
-
S
P
Multiple quantity
distance
2 - 24 pcs.
0 - 5000 mm
2
10
1 pcs.
1 mm
S
P
Delayed stop at
1 - 250 mm
10
1 mm
S
P
Profiling factor
(only C9100) start
length
100 - 200 %
1 - 500 mm
1 - 500 mm
100
1
2.5
1 %
1 mm
1 mm
S
P
Programs
1 - 32
1
-
S
P/O
Program identification
7 digits
blank
-
S
P
User levels
2
1
-
S
P/O
Password
0000 - 9999
0
-
S
P
Languages
8
De
-
S
P/O
Direction of rotation
left / right
R
-
S
P
Polarity IFEED
pos. / neg.
pos.
-
S
P
Nonstop mode
on/off
off
-
S
P
User menu
3 lines
-
any
S
P
Error handling
15 messages
0
any
S
P
Counter
999.999
-
1
R/S
P/O
Preset counter
999.999
0
1
R/S
P/O
Counter selection
GSC, LSC, EXT
GSC
-
S
P
R
= RUN
S
= STOP
P
= Programmer
O
= Operator
5999.530-01B 13.08.98 WM
Page 44 /