Error #10 Counter LSC
Cause:
When braking the label, a gap was detected during predispensing. This happens in the
case of transparent or very reflective labels.
Solution:
Adjustment of suppression of label scanner
Optimizing the positioning of label scanner
Optimizing the label scanner sensitivity
Error #11 Drive not ready
Cause:
The motor drive card indicates that it is not ready to drive the stepper motor.
Solution:
Switch off the monitor. Wait 10 seconds before switching on again. If the error did not
disappear, the monitor is damaged and has to be repaired by a specialist.
Error #12 Undervoltage
Cause:
During labelling a mains occurred causing the data to be backed up.
The monitor continues to operate normally.
Error #13 Profiling speed
Cause:
The max. profiling speed exceeds the maximum permissible labeller speed.
Solution
Reduce the goods speed or possibly increase the max. labeller speed.
Error #14 Time supervision
Error #15 Division by 0
Cause:
An internal protective circuit has detected that the calculation time provided is excee-
ded or a calculation error is in the processor. The cause may be a very strong electro-
magnetic disturbance or a program error.
Solution:
Switch off and on the monitor. If the error persists, please note all monitor settings and
contact your technical supporter.
Error #16 Predispensing too short
Cause:
At the actual measured speed the brake ramp exceeds predispensing.
Solution:
Reduce the good speed or increase predispensing.
5999.530-01B 13.08.98 WM