Error handling
The behavior of the labeller after appearance of an error is programmed with the
Error
Handling
function. Each error is indicated and
must
be acknowledged by the
ENTER
key. Each error can be programmed so that the labeller
STOP
s o the error message is
only indicated. If the labeller is stopped due to an error, then the signal relays
ERROR
and
NOK
are energized. If the labeller is not stopped, only the relay
NOK
is energized.
With the error key the error No. can be selected. Depress key
0
or
1
to select
Continue
or
Stop
. Depress the
POINT
key
to suppress the error identification (
ignore
).
[ / ] Error-No.
[0/1/.] Cont./Stop
Continue at
Label Stock
The following types of errors can be selected for error handling:
Not Ready
No LSC-Adjust.
Profiling Speed
TUNIT / Paper end
Nonstop mode
Time Control
Position too short
Label too long
Division by zero
Max. Speed
LSC Counter
Predispensing too short
Label Stock
Drive not ready
Rewinder full
Undervoltage
The exact description of the error messages and their prevention are
described in the chapter 'Error messages' in the Technical Appendix.
Nonstop mode
The
Nonstop mode
function allows continuous labelling with two labellers. The dis-
pensers are connected together and exchange signals. There is a difference between
the two dispensers. The first labeller in feed direction is the
MASTER
labeller and con-
trols the second labeller called
SLAVE
labeller. When selecting the nonstop mode the
labeller has to be defined as
MASTER
or
SLAVE
with
up
or
down
key:
NONSTOPMODE
Function : MASTER
programmer
STOP
User level:
Operating mode:
programmer
STOP
User level:
Operating mode:
5999.530-01B 13.08.98 WM
Page 30 /