Auto adjust
When adjusting the sensitivity automatically, the paper web has to be pulled forward by
depressing the
up
key, until the label scanner is positioned over the gap. A lateral mark
on the scanner head shows the position of the label scanner. The automatic adjustment
is started by depressing the
ENTER
key or abandoned by depressing the
ESC
key. Af-
ter adjustment the found value is indicated. If the scanner can not be adjusted on the
paper web, an error message will be issued.
AUTO ADJUST
AUTO ADJUST DONE
Move Label with
to the Gap and then
TCY-Value 50 %
press [ENTER] Key
User level:
programmer/operator
Operating Mode:
STOP
Manual adjust
When adjusting the sensitivity manually, the value is entered by hand. Entering can be
aborted by depressing the
ESC
key. This function will especially be used above all for
the adjustment of labels made of 'difficult' material.
LABEL SCANNER SENS.
TCY-Value 50 %
Gap
Label
Dispensing edge
Mark
Labelscanner
programmer
STOP
User level:
Operating mode:
5999.530-01B 13.08.98 WM
Page 16 /
49