background image

CRUSHED ICE MAKER WITHOUT BIN

AIR-CONDENSED

WATER-CONDENSED

TYPE: G250A, G500A, G1000A 

Installation and Operation Manual

S/N: 

Rev.: 2.4

Summary of Contents for G1000A

Page 1: ...CRUSHED ICE MAKER WITHOUT BIN AIR CONDENSED WATER CONDENSED TYPE G250A G500A G1000A Installation and Operation Manual S N Rev 2 4 ...

Page 2: ......

Page 3: ...ppliance The instructions and hints in this manual will give you a quick and easy start and you will soon note how nice it is to use the Metos equipment All rights are reserved for technical changes You will find the main technical data on the rating plate fixed to the equipment When you need service or technical help please let us know the serial number shown on the rating plate This will make it...

Page 4: ...18 9 2007 Rev 2 4 ...

Page 5: ...2 Designed use of appliance 3 3 2 1 Other than instructed use 3 3 3 Structure 3 3 4 Functioning principle 3 3 4 1 Switches and signal lights 4 4 Use instructions 5 4 1 Before use 5 4 1 1 Preparations 5 4 2 Use 5 4 3 After use 6 4 3 1 Cleaning 6 4 3 2 Scheduled maintenance 6 4 3 3 Layup 6 5 Installation 7 5 1 General 7 5 1 1 Using conditions 7 5 2 Possible disturbances from environment to environme...

Page 6: ...s 10 5 10 Connection to water mains 11 5 10 1 Connection to the cold water 11 5 10 2 Connection to water drain pipe 12 5 11 Distance of other fixtures 12 5 12 The probe in the bin 13 6 Main causes of operating failure 14 7 Technical specifications 15 ...

Page 7: ...orized by the manufacturer and using original spare parts Not complying with the above may put the safety of the appliance in danger 1 1 Symbols used in the manual This symbol informs about a situation where a safety risk might be at hand Given instruc tions are mandatory in order to prevent injury This symbol informs about the right way to perform in order to prevent bad results appli ance damage...

Page 8: ...rvention on the part of persons who are not competent in addition to being dangerous may cause serious damage to it In the event of a failure contact the dealer who sold you the appliance he will be able to give you the address of your nearest Authorized Technical Service Centre We recommend that you insist on having always and exclusively original spares 2 3 Disposal of appliance Should you decid...

Page 9: ...the production of crushed ices from cold drinking water is to be considered as improper use 3 3 Structure The supporting structure of the crushed ice maker is of steel and the outer panels are of stainless steel 3 4 Functioning principle The coolant in the cooling system freezes the evaporator to a temperature of 15 C A wa ter pump sprays an even jet of water into the cylinder shaped evaporator Wh...

Page 10: ...18 9 2007 Rev 2 4 Functional description 4 3 4 1 Switches and signal lights A switch on the front panel switches ON and OFF the appliance ...

Page 11: ...tem Turn on the water sypply tap switch on the power by means of the reletive switch fitted during the installation phase For appliances that are connected permanently to the electricity main turn on by means of the switch on the outside of the appliance fitted during the installation phase 4 2 Use Start the appliance by pressing the switch on the front panel After about 15 min in startups the cru...

Page 12: ...ents or powders since these might damage the surfaces All cleaning operations must be carried out only after the power and water supply have been disconnected as described previously For cleaning operations from the inside and disinfection of the appliance must be carried out by professionally qualified and authorized staff 4 3 2 Scheduled maintenance We recommend that you ask your dealer to draw ...

Page 13: ...tioned at a distance of at least 5 cm from the side walls 5 2 Possible disturbances from environment to environment If installation is carried out incorrectly damage and or injury may ensue to the environ ment persons animals or things The manufacturer declines all responsibility for any such damage or injury 5 3 Storage The net weight and the weight including packaging of the crushed ice maker ar...

Page 14: ... not use it and contact immediately the dealer who sold it to you Some models are equipped with special threaded holes for the attachment of eyebolts Lift the appliance using equipment fit to bear its weight and remove the appliance from the wooden pallet 5 6 Disposal of packaging All the packaging items plastic bags cardboard polystyrene foam nails etc must not be left within reach of children in...

Page 15: ... it s recommended to have the structure examined by a technical expert to make sure it is sta ble If the crushed ice maker installing on a container on our production the direction be found along the container The manufacturer declines all responsibility for installations made on containers not pro duced by our company Use a spirit level to check that the crushed ice maker is standing perfectly le...

Page 16: ...by professionally qualified and authorized staff The manufacturer declines all responsibility for damage and or inju ry that might ensue from any failure to earth the system properly It is essential that the electrical wiring system where the appliance is to be installed should have adequate cur rent carrying capacity for the maximum power of the appliance as shown on the data plate To achieve a p...

Page 17: ...r turn the water supply tap off when the appliance is working Where the feed water is particularly hard you are advised to install a softener Any solid particles e g sand may be eliminated by installing a mechanical filter which must be periodically inspected and cleaned These filters must be in compliance with the relevant national standards in force Insert the special seals provided in the two t...

Page 18: ... 5 on it s entire length and there are on air pockets in the pipe Direct the water drain pipe into an open drain trap head of the pipe must stay over on drain trap 5 11 Distance of other fixtures Do not obstruct the ventilation and heat dissipation grills since poor aeration in addition to reducing efficiency and causing poor operation may also cause serious damage to the appliance Leave distance ...

Page 19: ...8 9 2007 Rev 2 4 Installation 13 5 12 The probe in the bin Loosen the probe cautiously down from the machine Attach the capillary tube into the wall of the bin and attach the probe into the probe bracket ...

Page 20: ... still to present malfunction ing switch off the power supply via the switch provided during the installation phase pull out the plug from its socket close the tap connecting the appliance up to the water supply and call the nearest Authorized Technical Service Center In order to obtain a faster and more efficient intervention when you call the Center indi cate the model of the appliance precisely...

Page 21: ...hnical specifications 15 7 Technical specifications Electric diagram G250 G500 valid from 2004 07 22 Electric diagram G1000 valid from 2006 05 26 Installation drawing G 500A Installation drawing G 1000A Installation on bin ...

Page 22: ... CONTROLLO MANCANZA ACQUA BACINELLA BASIN S WATER S LACK MICRO SWITCH 11 TERMOSTATO CONTENITORE BIN THERMOSTAT 13 PRESSOSTATO CONTROLLO CONDENSAZIONE CONDENSER CONTROL PRESSURE SWITCH 15 TELERUTTORE CONTACTOR 17 MICRO CONTROLLO LIVELLO ACQUA BACINELLA BASIN WATER S LEVEL MICRO SWITCH 18 CONTROLLO CONTENITORE PIENO STORAGE BIN CONTROL 19 PRESSOSTATO DI SICUREZZA SAFETY PRESSURE SWITCH 24 INTERRUTTO...

Page 23: ...2 5 0 2 2 5 7 1 2 1 1 0 8 4 1 6 1 6 6 5 7 2 5 0 7 6 6 2 0 5 7 7 72 1 7 1 2 7 5 2 1 6 2 0 5 7 7 7 5 2 6 6 5 3 0 2 2 6 6 5 3 0 2 5 6 2 6 6 5 3 7 72 2 2 5 7 1 2 1 2 6 1 1 2 5 6 1 1 2 2 5 7 1 2 5 8 6 6 5 3 7 6 6 2 6 6 5 3 7 72 5 8 6 6 6 1 2 6 6 5 3 7 6 5 8 6 6 5 3 7 6 5 2 2 5 8 6 6 5 3 5 5 5 2 6 1 6 2 5 7 1 2 2 5 7 1 2 7 2 6 1 6 5 7 8 5 7 7 5 2 1 2 7 725 2 5 0 2 2 5 7 1 2 2 9 8 4 1 1 6 6 5 7 9 2 5 0 7...

Page 24: ...Installation drawing G 500A 1 Water OUT diam 24mm 2 Water IN diam 3 4 3 Power cable 640 mm 4 7 0 m m 700 mm G 500 A B C D E F 34 mm 228 mm 116 mm 282 mm 58 mm 292 mm C E A 1 3 2 F D B 3 2 1 ...

Page 25: ...ing G 1000A 1 Water OUT diam 24mm 2 Water IN condensator diam 3 4 3 Water IN basin diam 3 4 4 Power cable G 1000 700 mm 934 mm 6 8 4 m m A B C D E F 337 mm 60 mm 372 mm 187 mm 358 mm 257 mm C E A 1 4 3 2 F D1 B 3 1 4 2 ...

Page 26: ...Installation on bin ...

Page 27: ...240 1 50 Standard voltage 1000 220 240 1 50 Input power 250 3700W Input power 500 3700W Input power 1000 3700W Water consumption A 250 1 l kg Water consumption A 500 1 l kg Water consumption A 1000 1 l kg Water consumption W 250 5 2 l kg Water consumption W 500 5 3 l kg Water consumption W 1000 5 3 l kg Size WxDxH 250 640x470x700 mm Size WxDxH 500 640x470x700 mm Size WxDxH 1000 934x684x700 mm Size...

Page 28: ...18 9 2007 Rev 2 4 Technical specifications 22 A AIR CONDENSED W WATER CONDENSED 250 G250A 500 G500A 1000 G1000A A 3 N PE 400 230V 50Hz B 250V 16A 50Hz ...