2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
260
:MEASure:EGPRs:ARRay:RFTX:LENGth
Syntax
:MEASure:EGPRs:ARRay:RFTX:LENGth <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Measures multiple times (set with the int1 parameter) the burst length. To read out the entire measurement results
array, use the :FETCh:EGPRs:RFTX:LENGth command.
Query
The query form of this command returns a string, containing int1 floating point real numbers with the physical
dimension of microseconds, representing the measurement results.
The single measurement results are separated by commas.
Example
:MEAS:EGPRs:ARR:RFTX:LENG 5
:FETC:EGPRs:RFTX:LENG?
The measurement of the burst length is performed five times. The measurement results are stored internally and read
by the FETC command. An example of the string returned is: "556.4,557.2,558.2,557.8,556.5".
:MEASure:EGPRs:ARRay:RFTX:POWer
Syntax
:MEASure:EGPRs:ARRay:RFTX:POWer <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Measures multiple times (set with the int1 parameter) the burst peak power. To read out the entire measurement
results array, use the :FETCh:EGPRs:RFTX:POWer command.
Query
The query form of this command returns a string, containing int1 floating point real numbers with the physical
dimension of dBm, representing the measurement results.
The single measurement results are separated by commas.
Example
:MEAS:EGPRs:ARR:RFTX:POW? 5
An example of the string returned is: "11.22,11.09,11.21,11.14,10.99".