2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
236
:MEASure:GPRS:ARRay:RFTX:POWer
Syntax
:MEASure:GPRS:ARRay:RFTX:POWer <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Measures multiple times (set with the int1 parameter) the burst peak power. To read out the entire measurement
results array, use the :FETCh:GPRS:RFTX:POWer command.
Query
The query form of this command returns a string, containing int1 floating point real numbers with the physical
dimension of dBm, representing the measurement results.
The single measurement results are separated by commas.
Example
:MEAS:GPRS:ARR:RFTX:POW? 5
An example of the string returned is: "11.22,11.09,11.21,11.14,10.99".
:MEASure:GPRS:ARRay:RFTX:TEMPlate
Syntax
:MEASure:GPRS:ARRay:RFTX:TEMPlate <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Checks multiple times (set with the int1 parameter) if TX burst fits into the power/time template. To read out the
entire measurement results array, use the :FETCh:GPRS:RFTX:TEMPlate command.
Note: The power/time template is user-definable. It can be set up using the :CALC:GPRS:RFTX:TEMP commands.
Query
The query form of this command returns a string, containing int1 boolean numbers. A 0 indicates no violation of the
PTT by the current burst, while a 1 signals PTT violation.
The single measurement results are separated by commas.
Example
:MEAS:GPRS:ARR:RFTX:TEMP 10
:FETC:GPRS:RFTX:TEMP?
The check of the current burst against the PTT is performed ten times. The check results are stored internally and read
out by the FETC command. An example of the string returned is: "0,0,0,0,0,0,1,0,0,0", indicating that the seventh burst
checked violated the PTT.