2201R Mobile Tester SCPI Reference Guide
Chapter 10 Measurement commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
198
:MEASure:GSM[:CONTinuous]:RFRX:RBER:FER
Syntax
:MEASure:GSM[:CONTinuous]:RFRX:RBER:FER
Parameters
There are no parameters.
Description
Starts a continuous measurement of the frame erasure ratio. To read out the latest measurement result, use the
:FETCh:GSM:RFRX:RBER:FER command.
Notes:
- The number of samples to be used for testing can be set using the :CONF:GSM:BER:COUNt command.
Query
The query form of this command starts the measurement and returns a measurement result value as soon as the first
measurement has been completed. The string delivered back contains one floating point real number, representing
the frame erasure ratio.
Example
:MEAS:GSM:CONT:RFRX:RBER:FER?
Measurement result string delivered back:
"0.0".