2201R Mobile Tester SCPI Reference Guide
Chapter 8 Configuration commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
133
:CONFigure:GPRS:MSTAtion:PLEVel[:ALL]
Syntax
:CONFigure:GPRS:MSTAtion:PLEVel[:ALL] <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 31. The default value for int1 is 10.
Description
This command sets the mobile power control level.
Notes:
The RF power control level is a code. The corresponding RF output power of the mobile under test depends on the
type of GSM system and the frequency range.
The power control level is broadcast in the SACCH physical header.
Query
The query form of this command returns the current setting. The string delivered back contains one integer.
Example
:CONFigure:GPRS:MSTAtion:PLEVel:ALL 17
:CONF:GPRS:MSTA:PLEV?
Value returned: "17".
:CONFigure:GPRS:MSTAtion:MODE
Syntax
:CONFigure:GPRS:MSTAtion:MODE <PredefExp>
Parameters
PredefExp is one of the following predefined expressions: FACCh|SDCCh.
Default is FACCh.
Description
Defines whether the call setup takes place on FACCh or on SDCCh.
Note: There are two standard signaling channels in GSM: SDCCH and FACCH. The FACCH is always associated with a
traffic channel. However, some mobiles only listen to signaling provided on the SDCCH.
Query
The query form of this command returns the current setting. The string delivered back contains the short-form
version of one of the predefined expressions explained above.
Example
:CONFigure:GPRS:BS:CMODe FACCh
:CONF:GPRS:BS:CMOD?
Value returned: "FACC".