:CONFigure:EGPRs:MSTAtion:MSLot
Syntax
:CONFigure:EGPRs:MSTAtion:MSLot <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 1, the maximum value is 4. The default value for int1 is 2.
Description
This command either sets the number of UL time slots that the mobile under test is commanded to use during
multislot testing.
Query
The query form of this command returns the current setting. The string delivered back contains one integer.
Example
:CONFigure:EGPRs:MSTAtion:MSLot 4
:CONF:EGPRs:MSTA:MSL?
Value returned in this example: "4".
:CONFigure:EGPRs:MSTAtion:LOOPback
Syntax
:CONFigure:EGPRs:MSTAtion:LOOPback <PredefExp>
Parameters
PredefExp is one of the following predefined expressions: ON|OFF. Default is ON.
Description
Selects the loopback mode. If the parameter PredefExp is set to ON, the mobile station supports GPRS loopback
(mode B), if the parameter PredefExp is set to OFF, the mobile station does not support GPRS loopback (mode A).
Query
The query form of this command returns the current setting. The string delivered back contains one of the predefined
expressions as explained above.
Example
:CONFigure:EGPRs:MSTAtion:LOOPback ON
:CONF:EGPRs:MSTA:LOOP?