2201R Mobile Tester SCPI Reference Guide
Chapter 8 Configuration commands
47090/323
Copyright © 2016 Aeroflex Limited. All rights reserved.
116
:CONFigure:GPRS:BS:RLCMac:BSN:INC
Syntax
:CONFigure:GPRS:BS:RLCMac:BSN:INC <PredefExp1>
Parameters
PredefExp1 is one of the following predefined expressions: ON|OFF.
Default is ON.
Description
This command switches the auto-increment of the block sequence number either on (ON) or off (OFF) as long as the
2201R is working in (asynchronous) generator/analyzer mode (please refer to the description of the :CONF:CSYS:GPG
command for further information).
Query
The query form of this command returns the current setting. The string delivered back contains one of the predefined
expressions explained above.
Example
:CONFigure:GPRS:BS:RLCMac:BSN:INC OFF
:CONF:GPRS:BS:RLCM:BSN:INC?
Value returned: "OFF"
:CONFigure:GPRS:BS:ATTach
Syntax
:CONFigure:GPRS:BS:ATTach <PredefExp>
Parameters
PredefExp is one of the following predefined expressions: ON|OFF.
Default is OFF.
Description
Switches the IMSI Attach/Detach flag in the System Information messages broadcast on the BCCH on or off. If ON,
the mobile must register and deregister with the network simulated by the 2201R when switched on or off,
respectively. This can be used to detect when the mobile is switched on and listening to the 2201R network.
Query
The query form of this command returns the current setting. The string delivered back contains one of the predefined
expressions as explained above.
Example
:CONFigure:GPRS:BS:ATTach OFF
:CONF:GPRS:BS:ATT?
Value returned: "OFF".