:MEASure:GPRS:ARRay:RFRX:RBER:FER
Syntax
:MEASure:GPRS:ARRay:RFRX:RBER:FER <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for int1 is 0.
Description
Performs the measurement of the frame erasure ratio a specific number of times (set with the int1 parameter). To
read out the entire measurement results array, use the :FETCh:GPRS:RFRX:RBER:FER command.
Notes:
The number of samples to be used for testing can be set using the :CONF:GPRS:BER:COUNt command.
Query
The query form of this command performs the measurement the specified number of times (int1 parameter). As soon
as all measurements have been completed, all measurement result values are returned in a string. The string delivered
back contains int1 floating point real numbers, representing the frame erasure ratios.
The single measurement results are separated by commas.
Example
:MEASure:GPRS:ARRay:RFRX:RBER:FER 5
:FETCh:GPRS:RFRX:RBER:FER?
The string returned is: "0.0,0.1,0.0,0.2,0.1".