EXPORT IQ PLUS CHARGER (EXTERNAL)
Charging a Battery Pack that has Low Voltage
2008 Export Battery Charger Maintenance and Service Manual
Page 5-35
5
ý
WARNING
• The relay wiring must be properly connected prior to placing the charger back into normal
service. Failure to remove the jumper wire and properly connect the relay wiring could result
in property damage, severe personal injury, or death.
9. Install the charger cover and the retaining screws.
10. Plug the DC cord into the charger receptacle, then plug the AC cord into an electrical outlet.
11. Allow the charger to continue charging the batteries until the charger shuts off automatically.
12. When the charge cycle is complete, test the batteries again. If the battery pack voltage is above 34 volts
and the vehicle will not operate, it will be necessary to troubleshoot the vehicle’s electrical system to
determine which electrical component has failed.
See Section 11 – Electrical System and Testing in
the appropriate maintenance and service manual.
Figure 5-22 Export IQ Plus Charger Wiring Diagram (Relay Bypassed)
RELAY BYPASS
JUMPER WIRE
RELAY BYPASS
JUMPER WIRE