Provisioning settings
Provisioning Connectivity
This setting controls how the device discovers whether it should request an internal or
external configuration from the provisioning server.
Requires user role: ADMIN, USER
Default value: Auto
Value space: Internal/External/Auto
Internal: Request internal configuration.
External: Request external configuration.
Auto: Automatically discover using NAPTR queries whether internal or external
configurations should be requested. If the NAPTR responses have the "e" flag, external
configurations will be requested. Otherwise internal configurations will be requested.
Provisioning CUCM CallManagementRecords
Support for CUCM Call Management Records. This feature is experimental in this software
version.
Requires user role: ADMIN, USER
Default value: Off
Value space: Off/On
On: Enables support for CUCM Call Management Records.
Off: Disables support for CUCM Call Management Records.
Provisioning ExternalManager Address
Define the IP Address or DNS name of the external manager / provisioning system.
If an External Manager Address (and Path) is configured, the device will send a message
to this address when starting up. When receiving this message the external manager /
provisioning system can return configurations/commands to the unit as a result.
When using CUCM or TMS provisioning, the DHCP server can be set up to provide the
external manager address automatically (DHCP Option 242 for TMS, and DHCP Option
150 for CUCM). An address set in the Provisioning ExternalManager Address setting will
override the address provided by DHCP.
Requires user role: ADMIN, USER
Default value: ""
Value space: String (0, 64)
A valid IPv4 address, IPv6 address or DNS name.
Provisioning ExternalManager AlternateAddress
Only applicable when the device is provisioned by Cisco Unified Communication Manager
(CUCM) and an alternate CUCM is available for redundancy. Define the address of the
alternate CUCM. If the main CUCM is not available, the device will be provisioned by the
alternate CUCM. When the main CUCM is available again, the device will be provisioned by
this CUCM.
Requires user role: ADMIN, USER
Default value: ""
Value space: String (0, 64)
A valid IPv4 address, IPv6 address or DNS name.