Audio Ultrasound Mode
This setting applies to the Intelligent Proximity feature. Keep the setting at its default value.
Requires user role: ADMIN, INTEGRATOR
Default value: Dynamic
Value space: Dynamic/Static
Dynamic: The device adjusts the ultrasound volume dynamically. The volume may vary
up to the maximum level as defined in the Audio Ultrasound Volume MaxVolume setting.
Static: Use only if advised by Cisco.
Audio Ultrasound MaxVolume
This setting applies to the Intelligent Proximity feature. Set the maximum volume of the
ultrasound pairing messages.
The Audio Ultrasound MaxVolume and Proximity Mode settings only affect ultrasound
pairing messages. See the RoomAnalytics PeoplePresenceDetector and Standby
WakeupOnMotionDetection settings for information about the use of ultrasound in presence
and motion detection.
Requires user role: ADMIN, INTEGRATOR
Default value: 70
Value space: Integer (0..70)
Select a value in the specified range. If set to 0, ultrasound pairing messages are not
emitted.