![Cisco Small Business 300 1.1 Series Administration Manual Download Page 98](http://html.mh-extra.com/html/cisco/small-business-300-1-1-series/small-business-300-1-1-series_administration-manual_2609294098.webp)
Clock Commands
78-20269-01 Command Line Interface Reference Guide
99
6
Syntax
clock source {sntp}
no clock source
Parameters
sntp—Specifies that an SNTP server is the external clock source.
Default Configuration
There is no external clock source.
Command Mode
Global Configuration mode
Example
The following example configures an SNTP server as an external time source for
the system clock.
Console(config)#
clock source sntp
6.3
clock timezone
Use the clock timezone Global Configuration command to set the time zone for
display purposes. Use the no form of this command to set the time to Coordinated
Universal Time (UTC) or Greenwich Mean Time (GMT), which is the same.
Syntax
clock timezone
zone
hours-offset [minutes-offset]
no clock timezone
Parameters
•
zone—The acronym of the time zone.(Range: Up to 4 characters)
•
hours-offset—Hours difference from UTC. (Range: (-12)–(+13))
•
minutes-offset—Minutes difference from UTC. (Range: 0–59)