![Cisco Small Business 300 1.1 Series Administration Manual Download Page 242](http://html.mh-extra.com/html/cisco/small-business-300-1-1-series/small-business-300-1-1-series_administration-manual_2609294242.webp)
Remote Network Monitoring (RMON) Commands
78-20269-01 Command Line Interface Reference Guide
243
19
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field
Description
Alarm
Alarm index.
OID
Monitored variable OID.
Last Sample
Value
The value of the statistic during the last sampling
period. For example, if the sample type is delta,
this value is the difference between the samples
at the beginning and end of the period. If the
sample type is absolute, this value is the
sampled value at the end of the period.
Interval
The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds.
Sample Type
The method of sampling the variable and
calculating the value compared against the
thresholds. If the value is absolute, the variable
value is compared directly with the thresholds at
the end of the sampling interval. If the value is
delta, the variable value at the last sample is
subtracted from the current value, and the
difference is compared with the thresholds.