22-24
Cisco ONS 15454 Procedure Guide, R5.0
October 2005
Chapter 22 DLPs A500 to A599
DLP-A526 Change Line and Threshold Settings for the DS3i-N-12 Cards
describes the values on the Provisioning > Elect Path Thresholds tabs for the DS3i-N-12
cards.
describes the values on the Provisioning > SONET Thresholds tabs for the DS3i-N-12 cards.
ES
Errored seconds
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the
Show Thresholds
button.
SES
Severely errored seconds
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the
Show Thresholds
button.
LOSS
Loss of signal seconds; number
of one-second intervals
containing one or more LOS
defects
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the
Show Thresholds
button.
Table 22-2
Line Threshold Options for the DS3i-N-12 Cards (continued)
Parameter
Description
Options
Table 22-3
Electrical Path Options for the DS3i-N-12 Cards
Parameter
Description
Options
Port
(Display only.) Port number
1 to 12
CVP
Coding violations
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click the
Show Thresholds
button (DS3 Pbit: Near End only;
DS3 CPbit: Near and Far End).
ESP
Errored seconds
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
SESP
Severely errored seconds
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
SASP
Severely errored frame/alarm
indication signal–path
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
UASP
Unavailable seconds–path
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
AISSP
Alarm indication signal
seconds–path
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
Summary of Contents for ONS 15454 Series
Page 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...