G- and K-Series User’s Guide
1-8
Environmental (G-Series)
Table 1-3 shows the environmental specifications of the controllers:
<-6.5%, >+10.0 Controller shutdown
(failure)
<4.67 Vdc, 5.5 Vdc
+12V
+12 Vdc
0.6A max battery charging
0.1 A typical normal operation
0.2 A max normal operation
A/D Monitoring
±10.0% normal operation
(10.8 Vdc to 13.2 Vdc)
>±10% Degraded mode (warning alert)
(9.6 Vdc to 10.8 Vdc)
(13.2 Vdc to 14.4 Vdc)
>±20% Controller shutdown (failure)
<9.6 Vdc and >14.4 Vdc
Table 1-3. Environmental Specifications
Item
Specifications
Reliability
MTBF (Mean Time Between Failure): 200,000 power-
on hours
MTTR (Mean Time To Repair): 20 minutes
Temperature
Internal ambient operating:
5
o
C to 50
o
C maximum with specified air flow for
G5312
5
o
C to 45
o
C maximum with specified air flow for
G7313
Normal operating: 5
o
C to 50
o
C for SCSI host,
5
o
C to 45
o
C for FC host
Degraded mode operating: 0
o
C to 5
o
C and 50
o
C to 55
o
C
for SCSI host,
0
o
C to 5
o
C and 45
o
C to 55
o
C for FC host
Non-operating: -40
o
C to +100
o
C
Table 1-2. Electrical Specifications (Continued)
Item
Specifications
Summary of Contents for G5312
Page 1: ...G and K Series External RAID Board Controller G5312 G7313 K5312 K7313 User s Guide...
Page 2: ......
Page 10: ...G and K Series User s Guide viii...
Page 24: ...G and K Series User s Guide 1 14...
Page 28: ...G and K Series User s Guide 2 4...
Page 33: ...Accessing the Disk Array Administrator Software 3 5 Figure 3 1 Menu tree...
Page 34: ...G and K Series User s Guide 3 6 Figure 3 2 Menu tree continued...
Page 80: ...G and K Series User s Guide 6 8...
Page 138: ...G and K Series User s Guide 9 14...
Page 150: ...G and K Series User s Guide G 6...
Page 159: ......