G- and K-Series User’s Guide
7-16
3
Select
LUN Zoning
and press
Enter
.
The LUN Exclude List or LUN Include List screen displays. The default setting
for each array LUN is Include All Hosts. This results in all servers (hosts) being
able to access all arrays. You can change the list type using the Change Zone
Type option. See the next step.
4
Select the option you want and press
Enter
.
–
Display Host List—
Displays a list of the servers (hosts) currently on the
include or exclude list for the selected array. This option only displays
servers if you have already used Add Host to List and added one or more
WWNs to an include or exclude list.
–
Add Host to List
—Displays the Enter Host WWN screen where you enter
the WWN or name (alias) or select the server you want to add to the current
list for the selected array. Enter the WWN or name (alias) or select the server
from the list and press
Enter
.
–
Remove Host from List
—Displays the Remove Host from List screen
which contains a list of the servers (hosts) currently on the include or
exclude list for the selected array. Select the WWN of the server you want to
remove from the list and press
Enter
.
–
Change Zone Type
—Displays the Change Zone type screen where you can
change the type of zoning to one of four options described below. Changing
the zone type does not add or remove any hosts in previously created lists.
Summary of Contents for G5312
Page 1: ...G and K Series External RAID Board Controller G5312 G7313 K5312 K7313 User s Guide...
Page 2: ......
Page 10: ...G and K Series User s Guide viii...
Page 24: ...G and K Series User s Guide 1 14...
Page 28: ...G and K Series User s Guide 2 4...
Page 33: ...Accessing the Disk Array Administrator Software 3 5 Figure 3 1 Menu tree...
Page 34: ...G and K Series User s Guide 3 6 Figure 3 2 Menu tree continued...
Page 80: ...G and K Series User s Guide 6 8...
Page 138: ...G and K Series User s Guide 9 14...
Page 150: ...G and K Series User s Guide G 6...
Page 159: ......