Troubleshooting
9-3
The default setting is 1% backoff. This default allows you to easily work with drives
that have the same nominal capacity, but different actual capacities. The backoff
percentage affects all arrays created on the controller after you set the percentage.
If the drives in an array are not equal in size, the array capacity in a RAID-5 array is
based on the smallest member’s capacity. The backoff percentage is then backed off
the capacity from that amount.
To change the backoff percentage:
1
From the System Menu, select
Configuration Menu
and press
Enter
.
The Configuration Menu displays.
2
Select
Backoff Percent
and press
Enter
.
The Backoff Percent screen displays.
3
Enter the backoff percent you want to use and press
Enter
.
Enter the percentage as three digits in the following format: 00.0%. The default
is 01.0%.
Host SCSI Channel Problems
Problem: The host SCSI BIOS scan displays “Device name not available.”
The controller is properly connected, but no arrays have been created. Use the Disk
Array Administrator to create an array and reboot the host system.
Problem: The host SCSI BIOS scan hangs.
Check that termination is set correctly in the Configuration Menu and the drive
enclosure. Check that the device ID set in the Disk Array Administrator does not
Summary of Contents for G5312
Page 1: ...G and K Series External RAID Board Controller G5312 G7313 K5312 K7313 User s Guide...
Page 2: ......
Page 10: ...G and K Series User s Guide viii...
Page 24: ...G and K Series User s Guide 1 14...
Page 28: ...G and K Series User s Guide 2 4...
Page 33: ...Accessing the Disk Array Administrator Software 3 5 Figure 3 1 Menu tree...
Page 34: ...G and K Series User s Guide 3 6 Figure 3 2 Menu tree continued...
Page 80: ...G and K Series User s Guide 6 8...
Page 138: ...G and K Series User s Guide 9 14...
Page 150: ...G and K Series User s Guide G 6...
Page 159: ......