Creating and Managing Arrays
4-15
Verifying an Array
The Verify function allows you to verify the data on the specified array (RAID 3,
RAID 4, RAID 5, RAID 50, and mirrored arrays only):
!
RAID 3, RAID 4, RAID 5, and RAID 50—Verifies all parity blocks in the
selected array and corrects any bad parity.
!
Mirrored—Compares the primary and secondary drives. If a mismatch occurs,
the primary is copied to the secondary.
You may want to verify an array when you suspect there is a problem.
To verify an array:
1
From the System Menu, select
Array Menu
and press
Enter
.
The Select Array screen displays with a list of existing arrays.
2
Select the array you want and press
Enter
.
The Array Menu screen displays.
3
Select
Verify Function
and press
Enter
.
The verify menu displays.