9-11
Disk Channel Errors
Disk channel errors are similar to disk detected errors, except they are detected by the
controller, instead of the disk drive. Some disk channel errors are displayed as text
strings, others are displayed as hexadecimal codes.
11
01
Read retries exhausted
11
02
Error too long to correct
11
03
Multiple read errors
11
04
Unrecovered read error—auto reallocate failed
11
0B
Unrecovered read error—recommend reassignment
11
0C
Unrecovered read error—recommend rewrite the data
47
00
SCSI parity error
48
00
Initiator detected error message received
Table 9-4. ASC and ASCQ descriptions (Continued)
ASC
ASCQ
Descriptions